2005-05-19 00:00:00 | DENIED |
| |
| 1)A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 2) THE TYPICAL WALL SECTION ON SHEET A2 |
| SPECIFIES 2X8 #2 SYP FOR THE CEILING |
| JOISTS AND SECTION 3 ON A3 CALLS FOR |
| 2X10 #2 DENSE SYP. REVISE PLANS TO |
| INDICATE WHICH ONE IS TO BE USED. |
| |
| 3) THE ROOF NOTES ON A3 REFER TO ROOF |
| TRUSSES AND STATE THAT TRUSS ENGINEER IS |
| RESPONSIBLE FOR THE FINAL ROOF AND FLOOR |
| TRUSS LAYOUT. IF MANUFACTURED TRUSSES |
| ARE NOT BEING USED PLEASE REVISE OR |
| REMOVE THESE NOTES AS THEY DO NOT |
| PERTAIN TO THE DESIGN OF THIS PROJECT. |
| |
| 4) SPECIFY COLLAR BEAMS OF 1X6 BOARDS |
| INSTALLED TO EVERY THIRD PAIR OF RAFTERS |
| AS REQUIRED BY FBC 2309.1.7. |
| |
| 5) FLOOR JOISTS ARE REQUIRED TO BE |
| SUPPORTED LATERALLY AT THE ENDS BY SOLID |
| BLOCKING OR DIAGONAL STRUTS OR OTHER |
| METHOD. PLEASE SPECIFY METHOD THAT WILL |
| BE USED. SEE FBC 2307.3.4. |
| |
| 6) SUBMIT THE NOA OR EVALUATION REPORTS |
| AND INSTALLATION INSTRUCTIONS IN |
| ADDITION TO THE STATE COVERSHEETS FOR |
| THE SINGLE HUNG WINDOWS AND THE STORM |
| PANELS. |
| PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. |