Plan Review Notes For Permit 05021334 |
Permit Number |
05021334 |
|
Review Stop |
B |
Sequence Number |
14 |
|
Notes |
Date |
Text |
2005-09-14 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | 1.)REVISE ALL SHEETS AFFECTED BY THE | | REVISION SUBMITTED - SITE PLAN, A0.1, | | ANY OTHER SHEETS AFFECTED BY THE | | PROPOSED KIOSK OR RAMP DETAIL. | | | | 2.)8 1/2 X 11 SHEETS CAN BE SUBMITTED | | AS SUPPLEMENTARY OR ALTERNATE DETAILS | | BUT REVISIONS TO THE BUILDING PLANS | | SHOULD REVISED ALL AFFECTED SHEETS. | | | | 3.)DIMENSIONS ON A0.1 SHOWING CODE | | COMPLIANCE FOR THE RAMP WERE NOT ON THE | | DETAIL PROVIDED.WHEN REVISING A0.1 | | PLEASE INCLUDE ALL NECESSARY DIMENSIONS. | | | | 4.)SHOW THE MANEUVERING CLEARANCE FOR | | THE BREAK ROOM DOOR, FBC11 FIGURE 25. | | | | 5.)PROVIDE OPENING WIDTH BETWEEN THE | | BLOCK WALLS LEADING TO THE RAMP. | | | | 6.)SEPARATE PERMIT REQUIRED FOR THE | | PREFAB KIOSK. |
|