Date |
Text |
2005-04-12 00:00:00 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| |
| FBC FLORIDA BUILDING CODE 2001 |
| FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| TO THE FBC2001 |
| |
| 1.) A NOTICE OF COMMENCEMENT MUST BE |
| FILED WITH THE CLERK OF COURTS BEFORE A |
| PERMIT CAN BE ISSUED, FS713.13. |
| |
| 2.) IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY.THE PLANS MUST BE STAMPED |
| AND THE RECEIPT ATTACHED TO THE |
| APPLICATION.561-233-5025 |
| |
| 3.) ADDITIONAL FEES DUE TO VALUE |
| ADJUSTMENT.2192SF X 76.96, 525 X 41.6, |
| TOTAL OF 190,536.SEE ATTACHED INVOICE. |
| |
| 4.) NO EMERGENCY MEANS OF ESCAPE |
| FBC1005.4.5 IS SHOWN ON THE PLAN.THE |
| PRODUCT APPROVALS SUBMITTED FOR THE |
| FRONT DOOR SHOW A GLAZED DOOR REQUIRING |
| IMPACT PROTECTION.SHOW THE EMERGENCY |
| MEANS OF ESCAPE ON THE PLAN AND SUBMIT |
| COMPLIANT PRODUCT APPROVALS. |
| |
| 5.)THE TEST REPORT FOR THE OVERHEAD |
| DOOR HAS A DESIGN PRESSURE LIMITATION OF |
| +46/-52.THIS IS NOT SHOWN ON THE STATE |
| PRODUCT APPROVAL PROVIDED.CLEARLY |
| INDICATE ON THE STATE PRODUCT APPROVAL |
| WHICH PRODUCT YOU ARE INSTALLING. |
| |
| 6.)CIRCLE THE .PDF FILE LINK ON THE |
| STATE PRODUCT APPROVAL SUBMITTED FOR THE |
| SLIDING GLASS DOOR. |
| |
| 7.)IN ADDITION TO THE FRONT DOOR, |
| OVERHEAD DOOR, SLIDING GLASS DOOR, |
| REFERENCED ABOVE, PRODUCT APPROVALS |
| (FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| WITH TEST REPORT AND INSTALLATION |
| INSTRUCTIONS) REQUIRED FOR: |
| ROOF TILE |
| SINGLE HUNG WINDOW |
| IMPACT PROTECTION WITH INSTALLATION |
| SCHEDULE, SEE ATTACHED |
| MULLIONS |
| |
| 8.)SIGN THE OWNER/AGENT LINE OF THE |
| ENERGY CALC, FBC13-103.1.2. |
| |
| 9.)SPECIFY DESIGN CRITERIA FOR |
| HANDRAIL AND GUARDRAIL SHEET 1, |
| FBC1608.2.1 AND 1608.2.2.NOTE THAT |
| DESIGN CRITERIA IS DIFFERENT FOR RAILS |
| WHICH SERVE AS A GUARDRAIL.ALSO SEE |
| FBC1026.5.1. |
| |
| 10.) PROVIDE STRUCTURAL DETAIL FOR THE |
| STAIRS, INCLUDING FIREBLOCKING. |
| |
| 11.) REMOVE OR CROSS OFF DETAILS ON D1 |
| WHICH DO NOT APPLY TO THIS JOB. |
| |
| 12.) PROVIDE WIND DESIGN INFORMATION ON |
| THE PLAN FBC1606.1.7. |
| |
| 13.) TYPICAL WALL SECTION, SHEET 6, |
| SHOWS 8 INCH RECESS FOR BLOCK.REVISE. |
| |
| 14.) PROVIDE A DRAFTSTOP DETAIL AND |
| SCHEDULE (ON THE FLOOR FRAMING PLAN), |
| FBC705.3. |
| |
| 15.) STRUCTURAL NOTES D1, 1, ROOF |
| NAILING SPECIFIED NOT COMPLIANT FOR ZONE |
| 3, FBC*TABLE 2306.1. |
| |
| |