Plan Review Notes
Plan Review Notes For Permit 05021036
Permit Number 05021036
Review Stop B
Sequence Number 1
Notes
Date Text
2005-04-05 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.) A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED, FS713.13.
  
 2.) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.561-233-5025
  
 3.) NAILING FOR ROOF SHEATHING, 1-A6 AND
 BB-A3 (6 IN OC) IS NOT COMPLIANT FOR
 ZONE 3, FBC*TABLE 2306.1.
  
 4.) ADDITIONAL FEES DUE TO VALUE
 ADJUSTMENT.1888SF X 76.96, 513 X 41.6,
 TOTAL OF 166640.SEE ATTACHED.
  
 5.) WINDOW/DOOR BUCK DETAIL, A6, SHOWS
 ATTACHMENT INTO WOOD FRAMING. OTHER
 DETAILS SHOW THE CONSTRUCTION AS CBS.
  
 6.) SPECIFY WINDOW AND DOOR SIZES.
 BEDROOM WINDOWS ARE TO COMPLY WITH
 EMERGENCY EGRESS REQUIREMENTS,
 FBC1005.4.
  
 7.) SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC.
  
 8.) PROVIDE REACTION LOADS, ROOF FRAMING
 PLAN.
  
 9.) DOOR 2 BETWEEN LAUNDRY ROOM AND
 GARAGE IS TO BE SOLID CORE,
 FBC?13-403.1.ABCD.
  
 10.) BB-A3 REFERS TO TRUSS PLAN FOR
 GIRDER DETAIL.THIS WAS NOT PROVIDED.
 NO CONNECTORS OR REACTION LOADS
 SPECIFIED FOR GIRDER CONNECTIONS.
  
 11.) AA-A3, PORCH DETAILS, REFERS TO
 MECHANICAL PAGE.
  
 12.) FLORIDA STATE PRODUCT APPROVAL DOES
 NOT APPEAR TO MATCH THE NOA PROVIDED.
 PROVIDE FLORIDA STATE PRODUCT APPROVAL
 AND CIRCLE WHICH PRODUCT YOU ARE USING
  
 13.) THE SAME DATA SHEETS WERE PROVIDED
 FOR FL18 AND FL19.I CANNOT DETERMINE
 COMPLIANCE WITH FAC9B72.
  
 14.) THE TWO SPEC SHEETS SUBMITTED FOR
 DOORS ARE FOR SINGLE DOORS.THE GLAZED
 DOORS ON THE PLAN ARE DOUBLE DOORS.
  
 15.) THE PLAN SHOWS A PANEL DOOR FOR THE
 FRONT DOOR.THIS SERVES AS THE
 EMERGENCY MEANS OF ESCAPE FBC1005.4.5.
 IF THIS DOOR IS TO BE GLAZED, CHANGE THE
 PANEL DOOR NOTE ON THE PLAN AND INDICATE
 THE EMERGENCY MEANS OF ESCAPE.
  
 16.) PRODUCT APPROVALS ALSO REQUIRED
 FOR:
 ROOF TILE
 SHUTTERS
 SINGLE HUNG WINDOWS
 OPAQUE DOOR
  
 PRODUCT APPROVALS NOT APPROVED PRIOR TO
 ISSUANCE WILL REQUIRE SEPARATE PERMITS
 FOR THOSE ITEMS.
  
 17.) COMPLETE A HURRICANE SHUTTER
 INSTALLATION SCHEDULE, SEE ATTACHED.
  
 18.) THIS PROPERTY IS IN THE FIRE
 DISTRICT.DECLARE A BUILDING TYPE
 FBC600.TYPE VI CONSTRUCTION NOT
 ALLOWED IN THE FIRE DISTRICT, FBC*102.1.
  
 19.) SHOW COMPLIANCE WITH FBC TABLE 600
 IN REGARDS TO FIRE RESISTANCE FOR
 EXTERIOR BEARING WALLS.
  
 20.) PROVIDE DESIGN CRITERIA FOR THE
 TRUSSES, TCLL, TCDL, BCLL, BCDL.BCLL
 TO COMPLY WITH FBC TABLE 1604.1.
  
 21.)SHOW ATTIC ACCESS LOCATION AND
 SIZE, FBC2309.6, 2309.7.
  
 22.)32" CLEAR OPENING REQUIRED FOR THE
 FRONT DOOR, FBC TABLE 1004.