Plan Review Notes
Plan Review Notes For Permit 05011527
Permit Number 05011527
Review Stop B
Sequence Number 1
Notes
Date Text
2005-02-03 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
 CORRECTIONS APPLY TO 05011528, 05011529
  
 1.)THE TITLE BLOCK IS TO INCLUDE THE
 PRINTED LICENSE NUMBER OF THE PERSON
 SEALING THE DOCUMENT FAC61G15-23.002.
  
 2.)SPECIFY ANCHOR DISTANCE FROM EDGE
 OF SLAB.
  
 3.)GUARDRAILS ARE TO COMPLY WITH
 FBC1608.2.2; SPECIFY (DO NOT JUST
 PROVIDE CODE NUMBER).
  
 4.)GUARDRAILS ARE TO COMPLY WITH
 FBC1015.3.A 4" OPENING BETWEEN
 PICKETS
 DOES NOT COMPLY.SPECIFY DISTANCE OF
 BOTTOM RAIL FROM SLAB.
  
 5.)SPEC STATES "1/2" X 6" WEDGE
 ANCHORS AT FRONT AND BACK".BACK OF
 WHAT?THE BACK OF THE RAILING TUBE IS
 AGAINST THE SLAB.IF I AM
 MISUNDERSTANDING THE SPECIFICATION
 PLEASE PROVIDE A PLAN VIEW FOR
 CLARIFICATION.