2005-02-08 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05011202
 ADD: 6450 SPARROW HAWK DRIVE
 CONT: RIF GROUP
 TEL: (561)239-5790
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 FL S S 481.219(2)(3) THE HEADER STRIP
 FOR THE ARCHITECT FIRM JEFFERY
 SILBERSTEIN ARCHITECT & ASSOCIATES,
 INC.
 DOES NOT HAVE THE FIRMS CERTIFICATE OF
 AUTHORIZATION IN THE HEADERSTRIP.
  
 2) SHEET A-2.0 MASTER BEDROOM EGRESS
 WINDOW# 10 IS A FIXED GLASS PANEL. THE
 ADJOINING WINDOW# 3 MEETS THE EGRESS
 REQUIREMENTS, CORRECT.
  
 3) SHEET A-2.0 ALSO INDICATES A DEN ON
 THE ZERO LOTLINE SIDE OF THE HOUSE,
 THERE IS ALSO A ATRIUM AND EXTERIOR
 DOORWAY, THE DEN CANBE USED FOR A
 SLEEPING ROOM REQUIRING A SECOND MEANS
 OF EGRESS THROUGH THE ATRIUM, NOTHING ON
 THE SURVEY INDICATES A ANY ACCESS/EGRESS
 EASEMENTS ON THE ZEERO LOT LINE SIDE OF
 THE HOUSE. THE ELECTRICAL PLAN ALSO
 INDICATES SMOKE DETECTORS AND ARK FAULT
 CIRCUIT BREAKERS WHICH ARE REQUIRED FOR
  
 BEDROOMS OR SLEEPING ROOMS.
 IF NOT USSED AS A SLEEPING ROOM THE
 SURVEY DOESN'T INDICATE A ACCESS
 EASEMENT FOR MAINTENCE OF THE ATRIUM, IN
 EITHER CASE A ACCESS/EGRESS EASEMENT
 SHALL BE REQUIRED.
  
 4)ONLY ONE SOILS REPORT SIGNED AND
 SEALED THE SECOND IS A COPY,
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 5) THE PRODUCT SUBMITTALS FOR WINDOWS
 AND GLAZED DOORS INDICATES "NO LARGE
 MISSLE TESTING". FL BLD CODE
 1606.1.5: COMPONENTS & CLADDING, PROVIDE
 2 COPIES(3 IF THRESH- OLD OR RESIDENT
 INSPECTOR) OF PRODUCT TESTING
 REPORTS,MISSING REPORTS ARE AS FOLLOWS:
 A) STORM SHUTTERS
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.FBC
 1606.1.4.
  
 6)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.SEE EXAMPLE SHEET.
  
 7)THE FRONT ENTRY DOOR INDICATES
 GLAZING, THE PRODUCT APPROVAL SUBMITTED
 FOR THIS DOOR INDICATES STORM SHUTTERS
 ARE REQUIRED.FBC 1005.4.5 (GLITCH
 AMENDMENTS JULY 1, 2003) REQUIRES AT
 LEAST ONE MEANS OF ESCAPE FROM A
 DWELLING WHEN SHUTTERED FOR IMPACT
 PROTECTION. THE MEANS OF ESCAPE SHALL BE
 WITHIN THE FIRST FLOOR OF THE DWELLING
 AND CAN NOT BE LOCATED IN A GARAGE.
 OCCUPANTS IN ANY PART OF THE DWELLING
 SHALL HAVE ACCESS TO IT WITHOUT HAVING
 TO PASS THROUGH A LOCKABLE DOOR NOT
 UNDER THEIR CONTROL. INDICATE HOW
 COMPLIANCE WILL BE ACHIEVED.
  
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026