2005-02-08 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 05011202 |
| ADD: 6450 SPARROW HAWK DRIVE |
| CONT: RIF GROUP |
| TEL: (561)239-5790 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 1) PLANS, SPECIFICATIONS,REPORTS OR |
| OTHER DOCUMENTS PREPARED BY THE DESIGN |
| PROFESSIONAL AND BEING FILED FOR PUBLIC |
| RECORD SHALL HAVE THE SIGNATURE AND |
| SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| TO THE DOCUMENT. |
| FL STATE STAT: 61G15-23.002 ENGINEERS |
| FL ATATE STAT: 61G16.003 ARCHITECTS |
| FL S S 481.219(2)(3) THE HEADER STRIP |
| FOR THE ARCHITECT FIRM JEFFERY |
| SILBERSTEIN ARCHITECT & ASSOCIATES, |
| INC. |
| DOES NOT HAVE THE FIRMS CERTIFICATE OF |
| AUTHORIZATION IN THE HEADERSTRIP. |
| |
| 2) SHEET A-2.0 MASTER BEDROOM EGRESS |
| WINDOW# 10 IS A FIXED GLASS PANEL. THE |
| ADJOINING WINDOW# 3 MEETS THE EGRESS |
| REQUIREMENTS, CORRECT. |
| |
| 3) SHEET A-2.0 ALSO INDICATES A DEN ON |
| THE ZERO LOTLINE SIDE OF THE HOUSE, |
| THERE IS ALSO A ATRIUM AND EXTERIOR |
| DOORWAY, THE DEN CANBE USED FOR A |
| SLEEPING ROOM REQUIRING A SECOND MEANS |
| OF EGRESS THROUGH THE ATRIUM, NOTHING ON |
| THE SURVEY INDICATES A ANY ACCESS/EGRESS |
| EASEMENTS ON THE ZEERO LOT LINE SIDE OF |
| THE HOUSE. THE ELECTRICAL PLAN ALSO |
| INDICATES SMOKE DETECTORS AND ARK FAULT |
| CIRCUIT BREAKERS WHICH ARE REQUIRED FOR |
| |
| BEDROOMS OR SLEEPING ROOMS. |
| IF NOT USSED AS A SLEEPING ROOM THE |
| SURVEY DOESN'T INDICATE A ACCESS |
| EASEMENT FOR MAINTENCE OF THE ATRIUM, IN |
| EITHER CASE A ACCESS/EGRESS EASEMENT |
| SHALL BE REQUIRED. |
| |
| 4)ONLY ONE SOILS REPORT SIGNED AND |
| SEALED THE SECOND IS A COPY, |
| PLANS, SPECIFICATIONS,REPORTS OR |
| OTHER DOCUMENTS PREPARED BY THE DESIGN |
| PROFESSIONAL AND BEING FILED FOR PUBLIC |
| RECORD SHALL HAVE THE SIGNATURE AND |
| SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| TO THE DOCUMENT. |
| FL STATE STAT: 61G15-23.002 ENGINEERS |
| FL ATATE STAT: 61G16.003 ARCHITECTS |
| |
| 5) THE PRODUCT SUBMITTALS FOR WINDOWS |
| AND GLAZED DOORS INDICATES "NO LARGE |
| MISSLE TESTING". FL BLD CODE |
| 1606.1.5: COMPONENTS & CLADDING, PROVIDE |
| 2 COPIES(3 IF THRESH- OLD OR RESIDENT |
| INSPECTOR) OF PRODUCT TESTING |
| REPORTS,MISSING REPORTS ARE AS FOLLOWS: |
| A) STORM SHUTTERS |
| PROVIDE STORM PANEL INFORMATION WITH |
| INSTALLATION SCHEDULE AND KEY PLAN WITH |
| SPECIFIC ANCHORS AND MOUNTING TO BE USED |
| FOR ALL NON-IMPACT GLAZING.FBC |
| 1606.1.4. |
| |
| 6)FL BLD CODE 2001 SECTION 103.6, |
| 1606.1.4, 1707.4 & 3401.7.2.4. |
| PROCEDURES: 1(B) A COMPLETE INSTALLATION |
| SCHEDULE SUMMARIZING & IDENTIFYING |
| OPENING SIZES, STORY HEIGHTS, UNIT MARK |
| NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM |
| BAR REINFORCING REQUIREMENTS, WALL PRES- |
| SURE ZONES, SLAT TYPES, ETC., SHALL BE |
| SUBMITTED AT TIME OF PERMIT APPLICATION |
| TO FACILITATE PLAN REVIEW AND PERMIT |
| ISSUANCE.SEE EXAMPLE SHEET. |
| |
| 7)THE FRONT ENTRY DOOR INDICATES |
| GLAZING, THE PRODUCT APPROVAL SUBMITTED |
| FOR THIS DOOR INDICATES STORM SHUTTERS |
| ARE REQUIRED.FBC 1005.4.5 (GLITCH |
| AMENDMENTS JULY 1, 2003) REQUIRES AT |
| LEAST ONE MEANS OF ESCAPE FROM A |
| DWELLING WHEN SHUTTERED FOR IMPACT |
| PROTECTION. THE MEANS OF ESCAPE SHALL BE |
| WITHIN THE FIRST FLOOR OF THE DWELLING |
| AND CAN NOT BE LOCATED IN A GARAGE. |
| OCCUPANTS IN ANY PART OF THE DWELLING |
| SHALL HAVE ACCESS TO IT WITHOUT HAVING |
| TO PASS THROUGH A LOCKABLE DOOR NOT |
| UNDER THEIR CONTROL. INDICATE HOW |
| COMPLIANCE WILL BE ACHIEVED. |
| |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |