2005-01-28 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)DETAIL 10-A3, LOUNGE SINK IS TO
 COMPLY WITH FBC11-4.24.3 (KNEE
 CLEARANCE), SINK DEPTH A MAX OF 6 1/2"
 DEEP (11-4.24.4), MOUNTED WITH THE RIM
 NO HIGHER THAN 34" (11-4.24.2).A KNEE
 CLEARANCE IS SHOWN BUT THAT CLEARANCE
 IS
 BLOCKED BY THE CABINETRY.NOTE THAT
 DETAILS 8-A3 AND 10-A3 CONFLICT IN SINK
 HEIGHT.
  
 2.)A1, BUILDING CODE CLASSIFICATION,
 LOAD DECLARES 39.PLEASE CLARIFY.
  
 3.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC, FBC 13-103.1.2.