2005-03-21 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | | | A) FROM PREVIOUS REVIEW: | | 1) SHT A.4 TOILET ROOM SHALL BE | | ACCESSIBLE. SUBMIT THE FOLLOWING | | DETAILS: (THE FOLLOWING DETAILS HAVE NOT | | BEEN ADDRESSED). | | F) HEIGHT 11-4.18.2 | | G) CLEAR FLOOR SPACE 11-4.18.3 | | H) FLUSH CONTROLS 11-4.18.4 | | K) EXPOSED PIPES AND SURFACES 11-4.19.4 | | M) LAV SHALL BE MINIMUM 15" OFF WALL TO | | CENTER ON THE 30" WIDTH OF THE CLEAR | | FLOOR SPACE. SEE FIG. 32. | | N) SPOUT EHIGHT 11-4.15.2 | | 0) PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING. | | 11-4.1.3(10)(A). | | ***************NEW COMMENT************ | | 1A) SHOW ON DETAIL FOR DRINKING FOUNTAIN | | 11-4.15.5 CLEARANCES | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|