2005-01-27 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 05010848 |
| ADD: 503 M ST |
| CONT: GRAYHAWL DEVELOPMENT |
| TEL: (561)662-8150 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| |
| 1)PROVIDE NOC RECORDED WITH THE CLERK |
| OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| |
| 2) INCLUDE ALL LICENSE NUMBER'S INTHE |
| TITLE BLOCKAS REQUIRED UNDER FAC |
| 61G15-23.002 AND FL S S 471.023. |
| |
| 3) HAND DRAWN CHANGES TO SEALED PLANS |
| ARE NOT PERMITTED SEE 471.025 |
| |
| 4) RESTROOMS INDICATE A 4" RISE FROM THE |
| ADJACENT GRADE SEE:11-4.1.3(1) AT |
| LEAST ONE ACCESSIBLE ROUTTE COMPLYING |
| WITH 11-4.3 SHALL CONNECT ACCESSIBLE |
| BUILDING OR FACILITY ENETRANCES WITH ALL |
| ACCESSIBLE SPACES AND ELEMENTS WITHIN |
| THE BUILDING OR FACILITY. |
| 11-4.1.2 VERTICAL ACCESSIBILITY, |
| NOTHING IN THIS CODE SHALL BE CONSTRUED |
| TO RELIEVE THE OWNER OF ANY BUILDING, |
| SSTRUCTURE OR FACILITY FROM THE DUTY TO |
| PROVIDE VERTICAL ACCESSIBILITY TO ALL |
| LEVELS ABOVE OR BELOW THE OCCUPIAABLE |
| GRADE LEVEL. |
| |
| 5) FL BLD CODE 1804.2.2 QUESTIONABLE |
| SOILS, WHERE THE BEARING CAPACITY IS |
| NOT DEFINETLY KNOWN OR IS IN QUESTION. |
| WHERE THE BEARING CAPACITY OF THE SOIL |
| IS NOT DEFINITLY KNOWN OR IS IN QUESTION |
| THE BUILDING OFFICIAL MAY REQUIRE EXPLOR |
| ATIONS, TEST OR OTHER ADEQUATE PROOF AS |
| TO THE PERMISSIBLE SAFE BEARING |
| CAPACITY. REQUIRED TEST AND RECOMMENDA- |
| TIONS SUBMITTED TO VERIFY BEARING CAPA- |
| CITY SHALL BE CERTIFIED BY A GEOTECH- |
| NICALREPORT FROM A DESIGN PROFESSIONAL |
| PROPERLY LICENSED IN THE STATE OF |
| FLORIDA. |
| |
| 6)PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. SEE |
| ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| |
| 7)FL BLD CODE 1606.1.5: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORTS,MISSING REPORTS ARE AS |
| FOLLOWS: |
| A) SOLID EXTERIOR DOORS |
| B) LOUVERS |
| C) TRUSS ANCHORS |
| D) ROOFING ASSEMBLIES |
| |
| 8) SHEET A-3 FOUNDATION REQUIRES: |
| 1804.1.3 THE BOTTOM OF THE FOUNDATION |
| SHALL EXTEND NO LESS THAN 12" |
| BELOW FINISH GRADE. |
| |
| 9) A-2 TIE BEAM NOTE 2121.2.3.2 NOTE IS |
| NOT APPLICABLEIT IS FOR HIGH VELOCITY |
| HURRICANE WIND ZONE DADE & BROWARD |
| COUNTIES. |
| |
| 10) A-3 NOTE DEALS WITH 2319.17.1.2 ALSO |
| DEALS WITH THE HIGH VELOCITY WIND ZONE, |
| DADE & BROWARD COUNTIES, NOT |
| APPLICABLE. |
| |
| BEFORE A PERMIT TO CONSTRUCT, MAY |
| BE ISSUED, IMPACT FEES MUST BE PAID TO |
| PALM BEACH COUNTY. THE ACTUAL PERMIT |
| SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT |
| ATTACHED TO THE PERMIT APPLICATION. |
| PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |