2005-09-19 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 THE FOLLOWING COMMENTS ARE FROM THE
 PREVIOUS REVIEW.NUMBERING WILL REMAIN
 THE SAME TO MAINTAIN CONSISTENCY.
  
 ALL CHANGES TO THE PLAN ARE TO BE
 CLOUDED.
  
 1.)SEE PROPERTY APPRAISER VALUATION
 ATTACHED.THIS IS AN OVER 50%
 IMPROVEMENT AND MUST COMPLY WITH
 FBC3401.7.2.6.THIS SECTION AFFECTS
 OTHER COMMENTS ON THIS LIST. (WAS
 ACKNOWLEDGED.)
  
 2.)ADDRESSED.
  
 3.)THIS APPEARS TO BE TWO UNITS; ONE
 UPSTAIRS, ONE DOWNSTAIRS.2ND FLOOR IS
 TO BE IMPACT GLASS, CITY OF WEST PALM
 BEACH IMPLEMENTATION STANDARD FOR
 HURRICANE MISSILE IMPACT PROTECTION,
 ITEM #13, SEE ATTACHED.SUBMIT A
 HURRICANE INSTALLATION PLAN INCLUDING
 WHERE THE SHUTTERS WILL BE STORED FOR
 SHUTTERS USED ON THE FIRST FLOOR.
  
 SECOND REVIEW COMMENT - THIS WAS
 ADDRESSED BY CHANGING THE
 SECOND FLOOR TO IMPACT AND A NOTE
 STATING THAT THE FIRST FLOOR SHUTTERS
 WOULD BE STORED IN THE UTILITY ROOM
 BELOW THE STAIRS.ONLY THE BUILDING
 OFFICIAL CAN APPROVE THE USE OF SHUTTERS
 ON A COMMERCIAL BUILDING.PLEASE SUBMIT
 A HURRICANE SHUTTER INSTALLATION PLAN
 FOR REVIEW.THIS IS TO INCLUDE ALL
 PERTINENT INFORMATION SUCH AS STORAGE
 LOCATION, SIZE OF STORAGE AREA, WHERE
 THEY ARE STORED IN THAT AREA, HOW THEY
 ARE SECURED IN THAT LOCATION; WHO IS TO
 INSTALL THEM; TIME ESTIMATE FOR
 INSTALLATION; WHEN THE SHUTTERS WILL BE
 INSTALLED, ETC.THIS MAY BE SUBMITTED
 SEPARATELY FROM PLAN REVIEW (NO FEE).
  
 PLAN WAS NOT CHANGED, STILL SHOWS
 SHUTTERS ON THE FIRST FLOOR, AND AN
 INSTALLATION WAS NOT SUBMITTED FOR
 REVIEW.
  
 4.)THE BALCONY (MEANS OF EGRESS FOR
 2ND FLOOR UNIT) IS TO COMPLY WITH
 FBC1014.1.SHOW FIRE RESISTANCE (UL
 ASSEMBLY OR CALCULATED FBC CHAPTER 7),
 PROVIDE DOOR FIRE RATING INFORMATION.
  
 SECOND REVIEW COMMENT - THE FIRE RATING
 FOR THE DOOR WAS
 PROVIDED.I BELIEVE THAT THIS WAS
 ADDRESSED BY SHOWING TWO LAYERS OF
 DRYWALL ON THE CEILING OF THE FIRST
 FLOOR UNIT.PROVIDE CALCULATED FIRE
 RESISTANCE FOR THE FLOOR/CEILING
 ASSEMBLY FBC709 (EACH COMPONENT AND
 TIME, SHOW TOTAL).
  
 UL L504 WAS SHOWN ON THE PLAN.PLEASE
 INCORPORATE A DETAIL INTO THE PLAN.
  
 5.)THE EXTERIOR STAIR IS TO COMPLY
 WITH FBC1006.2.4.SHOW FIRE RESISTANCE
 OF THE WALL.OPENINGS WITHIN 10' ARE
 TO BE 3/4 HR.INDICATE ON THE PLAN.
  
 SECOND REVIEW COMMENT - FIRE RESISTANCE
 OF THE WALL REQUIRED BY
 FBC1006.2.4 WAS NOT SHOWN.THERE IS A
 NOTE ON THE PLAN REGARDING OPENINGS.IT
 IS THE RESPONSIBILITY OF THE DESIGNER TO
 DETERMINE WHICH OPENINGS ARE TO BE
 PROTECTED.INDICATE ON THE ELEVATIONS,
 FLOOR PLAN OR A SCHEDULE. ALSO INCLUDE
 THE REAR BUILDING.SHOW RATED WALL
 REQUIREMENT ON THE FLOOR PLAN AS WELL AS
 A DETAIL SHOWING HOW IT COMPLIES.
  
 UL DESIGN U301 WAS SPECIFIED FOR THE NEW
 WALL.INCORPORATE THE DESIGN FOR FIRE
 RESISTANT WALLS INTO YOUR PLAN.YOUR
 WALL SECTION IS IN CONFLICT WITH THIS
 DETAIL.ALSO U301 HAS DRYWALL ON BOTH
 SIDES; APPEARS TO BE AN INTERIOR BEARING
 WALL, YOUR PLAN REQUIRES AN EXTERIOR
 APPLICATION WHICH MUST ALSO HAVE
 STRAPPING TO COMPLY WITH WIND
 REQUIREMENTS.PLEASE CLARIFY.
  
 HOW DOES THE EXISTING WALL COMPLY WITH
 THIS REQUIREMENT?ACCORDING TO THE
 ENERGY CALCS, THIS IS A FRAME WALL.
 PROVIDE A DETAIL AND SHOW COMPLIANCE.
  
 NOTE THAT FIRE RESISTANT WINDOWS REQUIRE
 IMPACT PROTECTION.THIS OPENING SHOULD
 BE INCLUDED IN THE PROPOSAL TO THE
 BUILDING OFFICIAL, INCLUDING HOW THE
 SECOND FLOOR WILL BE ACCESSED FOR
 INSTALLATION.
  
 6.)ADDRESSED.
  
 7.)ADDRESSED.
  
 8.)ADDRESSED.
  
 9.)FOR THE MODIFIED ROOF, INDICATE
 WHICH METHOD OF INSTALLATION YOU ARE
 USING.
  
 SECOND REVIEW - THIS SHOULD BE DONE BY
 CHOOSING ONE OF
 THE APPROVED ASSEMBLIES ON THE PRODUCT
 APPROVAL.
  
 NOT ADDRESSED.IF THIS IS NOT ADDRESSED
 CORRECTLY PRIOR TO PERMIT ISSUANCE, THE
 ROOF PERMIT NUMBER WILL BE VOIDED AND A
 SEPARATE PERMIT WITH SEPARATE FEES AND
 REVIEW WILL BE REQUIRED.
  
 10.)ADDRESSED.
  
 11.)BATHROOM DOOR ON THE FIRST FLOOR
 IS TO COMPLY WITH FBC11-11(1), CLEAR
 OPENING OF AT LEAST 29IN.
  
 NEW COMMENT - THIS IS REQUIRED ON SECOND
 FLOOR BATHROOMS AS WELL.PLEASE REVISE.
  
 12.)THE ELEVATIONS AND WALL SECTION DO
 NOT MATCH.IS THERE A PARAPET WALL?IF
 THERE IS, SHOW DRAINAGE FBC1503.4.
  
 NOT ADDRESSED.A NOTE WAS SENT THAT
 THIS IS EXISTING.PLEASE SEE COMMENT
 #1.SHOW ALL REQUIRED DRAINAGE WITH
 CALCULATIONS.
  
 13.)SUBMIT PRODUCT APPROVALS AND FIRE
 RESISTANCE INFORMATION IF APPLICABLE FOR
 THE FOLLOWING:
  
 EXTERIOR DOOR, FIRE RATED
 SINGLE HUNG WINDOW, FIRE RATED
 IMPACT SINGLE HUNG WINDOWS
  
 14.)THE ENERGY CALCS FOR THE FRONT
 BUILDING, 1ST FLOOR GIVES A SQUARE FOOT
 AREA OF1203, THE LETTER FROM THE
 ENGINEER GIVES AN AREA OF 1483.SECOND
 FLOOR ENERGY CALCS GIVES AN AREA OF 965,
 LETTER FROM ENGINEER STATES 685 AFTER
 THE ADDITION.PROVIDE AREA CALCS FOR
 THE REAR BUILDING, 1ST AND 2ND FLOORS.
 PLEASE COMPARE WITH ENERGY CALCS PRIOR
 TO RESUBMITTAL.
  
 15.)THE LETTERHEAD FOR THE ENGINEER IS
 REQUIRED TO HAVE THE CERTIFICATE OF
 AUTHORIZATION, FAC61G15.
  
 16.)SEE ATTACHED FS553.80(2)(B).A 4X
 PLAN REVIEW FEE WILL BE CHARGED IF
 COMMENTS ARE NOT ADDRESSED.