Plan Review Notes
Plan Review Notes For Permit 04120353
Permit Number 04120353
Review Stop B
Sequence Number 309
Notes
Date Text
2007-06-24 16:39:54BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6652
 E-MAIL: [email protected]
  
 SUBMITTAL ON 6/5/07 FOR ENGINEERING CALCS FOR
 ADDITIONAL FASTENERS, WITHOUT SHIMS, TO ADDRESS FIELD
 VARIATIONS ON WINDOW AND SGD HEAD AND JAMB GAPS.
  
 1)FBC 1606.1ALL FASTENER LOCATIONS SHALL
 INCORPORATE SHIMS TO REDUCE FASTENER ROTATION, AND
 REDUCE THE RISK OF FASTENERS BACKING OUT DUE TO CYCLIC
 WIND LOADING.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS