Plan Review Notes
Plan Review Notes For Permit 04120264
Permit Number 04120264
Review Stop B
Sequence Number 1
Notes
Date Text
2004-12-15 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. ENGINEER'S SEAL MISSING ON DETAIL
 DRAWING. SEAL ON SHEETS 1 & 2 NOT
 READABLE. RESEAL SHEETS 1 & 2.
  
 2. SCREEN ENCLOSURE WILL BE INSTALLED
 OVER EXISTING PAVERS AND FOOTING.
 SUBMIT DRAWING SHOWING SIZE OF ANCHORS &
 PAVERS. SHOW EMBEDMENT OF ANCHORS INTO
 FOOTING.BCAB RECOMMENDS PAVERS TO BE
 INSTALLED ON FOOTER WITH MAXIMUM OF 3/4"
 MORTAR.
  
 NOTE: SCREEN ENCLOSURE IS NOT TO BE
 INSTALLED ONTOP OF PAVERS INSTALLED IN A
 SAND BED.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713
2004-12-14 00:00:00 
  