Date |
Text |
2004-12-15 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 04111262 |
| ADD: 622 N FLAGLER PH 4 |
| CONT:FIRST CONSTRUCTION |
| TEL: (561)358-9289 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| |
| 1) FL BLD CODE 104.2.1.2 |
| ADDITIONAL INFORMATION REQUIRED, |
| DISCREPANCY, BETWEEN SHEETS 2A, 2B & |
| D-1. SEE THE REQUIREMENT 1007.8.3 FOR |
| TREAD DEPTH NOT BEING LESS THAN 11" |
| MEASURED 12" FROM THE SMALL RADIUS. |
| |
| 2) PROVIDE WHAT MATERIALS THE STRINGERS |
| WILL BE MANUFACTURED FROM. SEE 1007.1.1 |
| NONCOMBUSTIBLE MATERIALS FOR A TYPE I OR |
| TYPE II BLDGS. |
| |
| 3) SHEET D-1 PROVIDE THE SPACING BETWEEN |
| THE UPRIGHT PICKETS, |
| 1015.3 OPENINGS. OPEN GUARDRAILS |
| SHALL HAVE INTERMEDIATE RAILS OR ORNA- |
| MENTAL PATTERNS SUCH AS A 4" DIAMETER |
| SPHERE CAN NOT PASS THROUGH. A BOTTOM |
| RAIL OR CURB SHALL BE PROVIDED THAT WILL |
| REJECT THE PASSAGE OF 2" DIAMETER |
| SPHERE. |
| |
| 4) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE |
| STOP PARTITIONS, HORIZONTAL EXIT PART- |
| ITIONS, EXIT ENCLOSURES, AND FIRE |
| RATED WALLS REQUIRED TO HAVE PROTECTED |
| OPENINGS SHALL BE EFFECTIVELY AND |
| PERMANETLY IDENTIFIED WITH SIGNS OR |
| STENCILING IN A MANNER ACCEPTABLE TO THE |
| AUTHORITY HAVING JURISDICTION. SUCH IDEN |
| TIFICATION SHALL BE ABOVE ANY DECORATIVE |
| CEILING CEILING AND IN CONCEALED SPACES. |
| SUGGESTED WORDING" FIRE & SMOKE BARRIER |
| PROTECT ALL OPENINGS". |
| |
| 5) TYPE I /II BLDG NO COMBUSTIBLES IN |
| WALLS 609.2.1. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |