2009-01-23 11:56:12 | BUILDING PLAN REVIEW |
| PERMIT: 04111073 |
| ADD: 300 PEMBROKE PL WARREN LIBRARY |
| CONT: THE WEITZ CO |
| TEL: (561)468-5511 |
| |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| SUBMITTALS-SHOP DRAWING REVIEW: |
| SKYLINE STEEL |
| WARREN LIBRARY PHASE II |
| AREA-B FRONT ENTRY HANDRAILS |
| |
| ACTION: DENIED |
| SHEET# 1 |
| |
| 1) THE PLANS SUBMITTED AND WERE ISSUED WILL NEED ALSO |
| TO BE UPDATED TO MEET REQUIREMENTS OF 107.5.2 2001 FBC |
| STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE. BOTH THE |
| UPPER STAIRWAY AND LOWER STAIRWAY ARE MISSING |
| HANDRAILS. THE UPPER PORTION ARE MISSING HANDRAILS ON |
| BOTH OF THE OUTSIDE PARTS OF THE STAIR AND THE LOWER |
| STAIR IS MISSING THE HANDRAIL ON ONE SIDE. |
| 1997 CODE COMMENTARY STATES THAT REQUIREMENTS THAT |
| ATRAIRWAYS HAVE HANDRAILS ON BOTH SIDES IS ONE OF THESE |
| MAINSTREAMED PROVISIONS (FROM CHAPTER 11). HANDRAILS ON |
| BOTH SIDES AFFORDS AN AMBULATORY MOBILITY IMPAIRED |
| PERSON A MEANS OF SUPPORT ON HIS/HER PREFERRED SIDE IN |
| BOTH ASCENT AND DESCENT. THE 2004 CODE AND COMMENTARY |
| ALSO AGREE IN ON THIS CODE SECTION. |
| |
| 2) THE MISSING HANDRAILS SHALL BE CONTIUOUS HANDRAILS |
| AT THE INSIDE TURN OF STAIRS 1007.5.5 EXCEPTION# 2. |
| |
| SHEET# 2 |
| |
| 3) SECTION A AT THE BOTTOM OF THE HANDRAIL THE |
| HORIZONTAL EXTENSION DOES NOT INDICATE THE ELEVATION OF |
| THE LOWER HORIZONTAL MEMBER, MUST BE NO HIGHER THAN 27" |
| FROM THE FINISH FLOOR, PLEASE REVIEW |
| 11-4.4 PROTRUDING OBJECTS. NOTE THE SAME SITUATION |
| OCCURS ON SHEET# 1 SECTION-B. |
| |
| SHEET# 3 |
| |
| 4) UPPER DETAIL INDICATES AT THE CURB A HORIZONTAL |
| OPENING BETWEEN 5 1/2" TO 6 1/2" DEPENDING ON THE SLOPE |
| OF THE CURB. PLEASE REVIEW SECTION 1015.3 2001 FBC |
| OPENINGS TO REJECT A 4 " SPHERE. |
| |
| 5) SECTION A DOES NOT PROVIDE A OVER ALL HEIGTH FROM |
| THE FINISH FLOOR TO THE TOP OF THE RAIL. IT APPEARS THE |
| TOTAL OF ALL MEASUREMENTS DOES NOT THE MINIMUM OF 42" |
| IN HEIGHT SEE CIRCLED DIMENSIONS POSSIBLE ERROR? |
| SECTION 1015.2 2001 FBC. |
| |
| 6) COVERSHEET FOR CALCULATIONS: SIGNATURE IS COPIED, |
| INDEX SHEEET OR PAGE WILL REQUIRE ORIGINAL SEAL AND |
| SIGNATURE. |
| 61G15-23.002(2) FL. ADMIN. CODE. PLANS SIGNED & SEALED |
| BY A PROFESSIONAL ENGINEER SHALL INCLUDE EITHER THE: |
| NAME, ADDRESS AND LICENSE NUMBER OF THE ENGINEER OR, |
| THE NAME AND LICENSE NUMBER OF THE ENGINEER AND THE |
| NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER |
| OF THE ENGINEERING BUSINESS THROUGH WHICH THE ENGINEER |
| IS PRACTICING (471.025 F.S. AND 471.023 F.S.). |
| |
| 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR INDEX |
| SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED AND |
| THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE |
| PRODUCTION & PREPARATION OF EACH SECTION OF THE |
| ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION |
| ON THE COVER SHEET OR INDEX. |
| |
| 7) CALCULATION SHEET# 1 INDICATES THE STAIRHANDRAIL/ |
| GUARDRAIL SYSTEM IS DESIGNED TO THE 2004FBC AND CODE |
| NOTATIONS WWIWTHIN THE DOCUMENT REFLECT THIS , BUT THIS |
| PERMIT 04111073 IS A CURRENT AND ISSUED PERMIT UNDER |
| THE 2001 FBC, PLEASE CORRECT ALL NOTATIONS. |
| |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| |
| MEMBER OF BOAF, THE BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA: PROTECTING LIVES AND PROPERTY SINCE 1953. |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. UNDER FLORIDA STATE STATUTE SB 80, E-MAIL |
| ADDRESSES ARE PUBLIC RECORDS.WRITTEN COMMUNICATIONS TO |
| OR FROM LOCAL OFFICIALS REGARDING CITY BUSINESS ARE |
| PUBLIC RECORD, AVAILABLE TO THE PUBLIC UPON REQUEST. |
| YOUR E-MAIL COMMUNICATIONS ARE THEREFORE SUBJECT TO |
| PUBLIC DISCLOSURE. |
| |
| |
| |