2007-10-31 13:28:23 | BUILDING PLAN REVIEW |
| PERMIT:04111073 |
| ADD: 300 PEMBROKE PLACE |
| CONT: THE WEITZ CO |
| TEL: (561)687-4807 |
| |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| W/ 2007 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVISIONREVIEW DATED, ARCHITECT 9/28/07STRUCTURAL |
| 9/27/07 |
| ACTION: DENIED |
| |
| 1A)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| 1B)PLEASE SUBMIT 3 OF ALL SURVEYS, PLANS, REPORTS, |
| REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR |
| REVIEW FOR PERMIT. |
| YOUR PROJECT WILL REQUIRE A THRESHOLD INSPECTOR THEN |
| (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED |
| FOR PERMIT ISSUANCE.105.13/ 2001 FBC OR106.1* /2004 |
| SUBMITTAL DOCUMENTSWEST PALM BEACH ADMINISTRATIVE |
| CODE. |
| THIS IS A PHASED PERMIT, THE SECOND PHASE WILL ONLY |
| REQUIRE A THRESHOLD INSPECTOR UNTIL THE STRUCTURAL |
| COMPONENTS |
| |
| 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 |
| DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN |
| THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS |
| A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| DETERMINED BY THE BUILDING OFFICIAL. |
| |
| 1D ) NOTE, PRODUCT APPROVALS THAT WERE REVIEWED AS CODE |
| COMPLIANT UNDER THE 2001 FBC ARE STILL IN EFFECT |
| CURRENT, EVEN THOUGH THE REPORT EXPIRATION DATE MAY |
| HAVE PAST, THIS COMMENT HAS BEEN REVIEWED BY B.O. NEIL |
| MELICK. |
| |
| 2) ARCHITECT LOYD MEYERS PLEASE SEE FL ADIMISTRATIVE |
| CODE 61G1-16.002 SEALS TO BE APPROXIMAATELY 2" IN |
| DIAMETER. |
| |
| 3)SHEET A1.01 IS MISSING THE CERTIFICATE OF |
| AUTHORIZATION IN THE TITLE BLOCK FOR THE FOLLOWING |
| ENGINEERS, 471.023 F.S.CERTIFICATE OF |
| AUTHORIZATION.THE TITLE BLOCK FOR ANY SHEET BEARING |
| THE NAME OF AN ENGINEER PRACTICING UNDER A FICTITIOUS |
| NAME, A CORPORATION, OR A PARTNERSHIP, OFFERING |
| ENGINEERING SERVICES, SHALL INCLUDE THE CERTIFICATE OF |
| AUTHORIZATION NUMBER. ADD THE NUMBER TO EACH SHEET. |
| THIS MAY BE ADDED BY HAND. |
| |
| 3A) CIVIL, SHALLOWAY FOY RAYMAN & NEWELL |
| 3B) STRUCTURAL, SLIDER ENGINEERING GROUP |
| |
| 4) LANDSCAPING WINSTON LEE ASSOCATES, 481.219 F.S. |
| CERTIFICATE OF AUTHORIZATION.THE TITLE BLOCK FOR ANY |
| SHEET BEARING THE NAME OF AN ARCHITECT PRACTICING UNDER |
| A FICTITIOUS NAME, A CORPORATION, OR A PARTNERSHIP, |
| OFFERING ARCHITECTURAL SERVICES, SHALL INCLUDE THE |
| CERTIFICATE OF AUTHORIZATION NUMBER.ADD THE NUMBER TO |
| EACH SHEET.THIS MAY BE ADDED BY HAND. |
| |
| 5) THE ARCHITECTURAL SHEETS HAVE BEEN SEPERATED FROM |
| THE MEP SHEETS, UNABLE TO DO A COMPLETE REVIEW! |
| |
| 6)SHEET A4.06 DETAIL# 9 INDICATES TREATED WOOD |
| BLOCKING TO BE USED IN THE CUPOLA AS BLOCKING, PLANS DO |
| NOT MAKE IT CLEAR THIS IS TO BE FIRE RETARDANT TREATED |
| WOOD, TYPE II BUILDING CONCEALED SPACES, 609.2.1. |
| |
| 7)SHEET S4.10 INDICATES THE USE OF HELICAL PIER |
| SYSTEM, THE PLANS DO NOT CALL OUT AS TO THE TYPE OF |
| HELICAL ANCHOR TO BE USED, THE SIZE OF THE ANCHOR AND |
| THE UPLIFT LOADS AND GRAVITY LOADS THAT IT WILL BE |
| REQUIRED FOR IT TO RESIST. |
| ALSO NO GEOTECHNICAL REPORT HAS BEEN SUBMITTED |
| INDICATING THE MINIMUM SAFE BEARING VALUE THAT EACH |
| PIEER WILL NEED TO ASSUME.104.1.2/ 1606.1.3. PLANS |
| INDICATE THE EXTERIOR WALLS ARE TO BE SPRAYED WITH |
| CONCRETE, IS THIS TO BE GUNITE, IN EITHER CASE WHAT IS |
| THE MIX TO BE USED? |
| |
| 8) SHEET S4.07 NEEDS THE ENGINEER TO DATE STAMP ONE |
| SHEET OF STRUCTURAL PLANS. 102.1* WHERE, IN ANY |
| SPECIFIC CASE, DIFFERENT SECTIONS OF THIS CODE SPECIFY |
| DIFFERENT MATERIALS, METHODS OF CONSTRUCTION OR OTHER |
| REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE |
| THERE IS A CONFLICT BETWEEN A GENERAL REQUIREMENT AND A |
| SPECIFIC REQUIREMENT, THE SPECIFIC |
| REQUIREMENT SHALL BE APPLICABLE. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |