2004-11-17 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04110885
 ADD: 732 NATHAN HALERD
 CONT: PAUL E HAHN CCC023528
 TEL: (561)721-5908
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: REVIEWED
  
 1507.3.8 UNDERLAYMENT APPLICATION
 FOR ROOF SLOPES FROM 2:12 TO 4:12,
 UNDERLAYMENT SHALL BE A MINIMUM OF TWO
 LAYERS APPLIED AS FOLLOWS:
 1) STARTING AT THE EAVE, A 19-INCH
 STRIP OF UNDERLAYMENT SHALL BE APPLIED
 PARALLEL WITH THE EAVE AND FASTENED
 SUFFICIENTLY TO STAY IN PLACE.
 2) STARTING AT THE EAVE, 36-INCH-WIDE
 STRIPS OF UNDERLAYMENT FELT SHALL BE
 APPLIED OVER-LAPPING SUCCESSIVE SHEETS
 19"AND FASTENED SUFFICIENTLY TO STAY
 IN PLACE.
  