Plan Review Notes For Permit 04110638 |
Permit Number |
04110638 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2004-11-27 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING | | POOLS | | | | | | A) THE FOLLOWING INFORMATION IS REQUIRED | | ON THE PLANS FOR POOL PERMIT. PLEASE | | SUBMIT A DETAIL, MANUF. SPECIFICATIONS | | OR ADD INFORMATION TO NOTES AS | | REQUIRED. | | 1) COMPLY WITH FBC-2001 SEC 424.2 | | PRIVATE SWIMMING POOLS. | | 2) FBC-2001 SEC 424.2.6.1 ENGINEERING | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | ANSI/NSPI-5. (ADD TO NOTES) | | 3) FBC-2001 424.2.7.2 PUMPS AND | | EQUIPMENT SHALL BE MOUNTED ON A | | SUBSTANTIAL BASE IN A MANNER THAT WILL | | ELIMINATE STRAIN ON PIPING.SLAB SHALL | | BE A NOMINAL 4" THICK. (DETAIL) | | 4) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | ORD #2938-95, BACKFLOW REQUIRED ON THE | | WATER SERVICE. (ADD TO NOTES) | | 5) FBC-2001 424.2.12.1 PRESSURE TESTS. | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | FITTINGS. (ADD TO NOTES) | | 6) FBC-2001 424.2.13.2 JOINTS AND | | CONNECTIONS, FBC PLMG SEC 605.21, PURPLE | | PRIMER REQUIRED ON PVC PIPING AND | | FITTINGS. (ADD TO NOTES) | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|