2005-02-23 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | FROM PREVIOUS REVIEW: | | 1) KITCHEN SINK IS NOT VENTED. SECTION | | 901.2.1. - IF THIS IS AN AIR ADMITTENCE | | VALVE, THEN SHOW IT AS SUCH ON THE RISER | | DIAGRAM. | | 2) WASH MACHINE REQUIRES A STANDPIPE, | | AND THE CLEANOUT SHALL BE INSTALLED 4' | | ABOVE THE FLOOR FOR ACCESS. SECTIONS | | 1002.1 AND 708.10 | | 3) ANY PORTION OF THE DRAINAGE SYSTEM | | INSTALLED UNDERGROUND, SHALL NOT BE LESS | | THAN 2" IN DIAMETER. SECTION 710.3 | | | | 2) SEE SHEET 3/10 FOR RED LINE | | CORRECTIONS TO BE MADE TO THE SANT. | | RISER DIAGRAM. | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|