2004-11-22 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
  
 1) SHT 8 SANITARY RISER DIAGRAM DOES NOT
 MEET CODE REQUIREMENTS.
 A) THE WASH MACHINE SHALL NOT DRAIN
 THROUGH THE WET VENT FOR THE BATHROOM
 FIXTURES. THE WASH MACHINE SHALL
 DISCHARGE DOWNSTREAM OF THE BATHROOM
 FIXTURES. SECTION 909.1 - SECTION
 104.2.1.
 B) WASH MACHINE IS REQUIRED TO HAVE A
 STANDPIPE. SECTION 1002.1
  
  
 (SEE RED LINE EXAMPLE OF CORRECT PIPING
 ON SHT 8 OF ONE SET OF PLANS)
  
  
  
  