2004-10-07 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) FBC* 104.1.1NO ROOF COVERING
 INFORMATION SUBMITTED. A SEPARATE PERMIT
 APPLICATION IS REQUIRED.
  
 2) FBC 3401.7.2.2REPAIRS TO EXISTING
 BUILDINGS.STRUCTURAL REPAIRS SHALL
 COMPLY WITH THE REQUIREMENTS FOR NEW
 BUILDINGS OR STRUCTURES.SEE COMMENTS
 BELOW.
  
 3) FBC 1507.5.1ROOF SHEATHING.THE
 FIELD REPORT BY MICHAEL NALYWAJKO, P.E.
 STATES THAT A METAL ROOF SYSTEM IS TO BE
 USED. THIS WILL REQUIRE THE INSTALLATION
 OF A SOLID OR CLOSE-FITTED DECK.THE
 SUBMITTED PLANS DO NOT SHOW ANY DECK/
 SHEATHING.AMEND THE PLANS.
  
 4) FBC 1603.1WEIGHT OF PROPOSED ROOF
 CONSTRUCTION.A LOAD COMPARISON, OF NEW
 ROOF CONSTRUCTION AGAINST OLD, SHALL BE
 SUBMITTED TO SHOW THAT THE PROPOSED ROOF
 LOAD IS LESS, OR THAT THE EXISTING
 TRUSSES CAN SUPPORT THE ADDITIONAL LOAD.
  
 5) FBC 1606.2.4MAIN WIND FORCE
 RESISTING SYSTEM.IT IS NOTED THAT THE
 PLANS STATE THAT CONNECTION A (PURLIN TO
 EXISTING TRUSS) WILL BE TWO SIMPSON H5A
 (350# UPLIFT).IN ORDER TO VERIFY THE
 ADEQUACY OF THIS CONNECTION THE PLANS
 SHALL STATE THE MEAN ROOF HEIGHT, THE
 ROOF ANGLE/SLOPE AND WHETHER THE
 BUILDING IS OPEN OR ENCLOSED.
  
 6) FBC* 2306.1SHEATHING FASTENING
 SCHEDULE.THE FASTENER TYPE AND SPACING
 SHALL BE IN ACCORDANCE WITH THE CITY OF
 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS