Plan Review Notes For Permit 04100192 |
Permit Number |
04100192 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2004-11-23 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING | | POOLS | | | | | | A) THE FOLLOWING INFORMATION IS REQUIRED | | FOR THE POOL PERMIT. ADD TO NOTES, | | SUBMIT A DETAIL, OR SUBMIT MANUFACTURE | | SPECIFICATION SHEETS AS REQUIRED. | | 1) FBC-2001 424.2.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | SHEETS REQUIRED. (SUBMITTAL) | | 2)FBC-2001 424.2.14.2 WATER RETENTION, | | PROVIDE A POSITIVE MEANS OF RETAINING | | WATER IN THE HEATER WHEN PUMP IS SHUT | | OFF. (MANUF. CUT SHEETS SUBMITTAL). | | 3) FBC-2001 424.2.15 GAS PIPING SHALL | | COMPLY WITH FBC FUEL GAS. SEPARATE PLANS | | AND PERMIT REQUIRED. | | | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|