2004-10-13 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04090032
 ADD: 1950 PRESIDENTIAL WAY
 CONT: BAINES BUILDING COMPANY
 TEL: (561)718-3997
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) THIS PROJECT SHALL BE REVIEWED AS
 CONDOMINIUMS,THE PLANS INDICATE TOWN-
 HOUSE. IF THE PROJECT IS TO CONTINUE AS
 CONDOMINIUMS DELETE ALL REFRENCES TO
 "TOWNHOUSE" ON ALL PLANS. IF THE PROJECT
 IS TO CONTINUE AS TOWNHOUSE THEN THE
 PLAT NEEDS TO BE REPLATED INTO INDIVID-
 UAL LOTS.
  
 2) THE SECOND ISSUE WILL BE THE PERMIT
 COVERING THE 3 BUILDINGS UNDER ONE
 SINGLE PERMIT. NO CERTIFICATE OF OCCU-
 PANCY WILL BE ISSUED FOR ANY BUILDING
 UNTIL ALL BUILDINGS ARE COMPLETE.
  
 3) THE PROPOSED BUILDING STRUCTURE
 TRANSGRESSES LEGAL BOUNDARY LINES
 BETWEEN THE LOTS WHICH COMBINE TO FORM
 'THE SITE'.A 'UNITY OF TITLE' SHALL BE
 RECORDED AT THE COUNTY COURTHOUSE.
 SUBMIT A COPY OF THE RECORDED 'UNITY OF
 OF TITLE' DOCUMENT SO THAT FBC TABLE 600
 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED
 NOT APPLICABLE.
  
 4) 903.8.2 FLOR ST STATUTE 553.895(2)
 ALL RESIDENTIAL BUILD. 3 OR MORE STORIES
 TALL WHETHER DESIGNATED AS TOWNHOUSE,
 CONDOMINIUMS, "APARTMENT HOUSES,
 TENEMENTS, GARDEN APARTMENTS OR BY ANY
 OTHER NAME SHALL BE SUPPLIED BY FIRE
 SPRINKLERS MEETING NFPA 101.
  
 5)PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2001 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION.
 THE ENERGY FORMS SUBMITTED ARE FOR A
 SINGLE FAMILY USAGE, NOT WORST CASE FOR
 CONDO "MULTIPLE FAMILY".
  
 6) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL
 IS NOT DEFINITLY KNOWN OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL
 PROPERLY LICENSED IN THE STATE OF
 FLORIDA.
 PROVIDE GEOTECHNICAL REPORT BY THE
 TESTING LABS OF THE PALM BEACHES
 FILE# 04/213-1.
 IF THE REPORT DOES NOT PROVIDE INFORMA-
 TION ON THE AUGER PILE INSTALATION, PRO-
 VIDE INFORMATION REQUIRED IN 1809 FOR
 CAST-IN-PLACE CONCRETE PILE.WHO WILL
 SUPERVISE THE INSTALATION OF THE CAST
 AUGER PILE? WIDTH OF PILE?
  
 7) SHEET A-3 HAS NOTES ABOUT TOWNHOUSE
 SEPERATION UL# U905 IF NOT TOWNHOUSE
 DELETE NOTE, PROVIDE ACTUAL ASSEMBLY.
 ALSO FOR UL# U465.
 104.2.1 W.P.B. ADMINISTRATIVE CODE
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR
 OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES.
 SUCH INFORMATION SHALL BE SPECIFIC
 AND THE TECHNICAL CODES "SHALL NOT BE
 CITED AS A WHOLE OR IN PART, NOR THE
 TERM "LEGAL" OR ITS RQUIVALENT BE USED
 AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION".
  
 8) ALSO SHEET A-3 2ND & 3RD LEVEL, SEE
 GAURDRAILS:
 1015.2 HEIGHT. GUARDRAILS SHALL
 FORM A VERTICAL PROTECTIVE BARRIER NOT
 LESS THAN 42" HIGH.
 1015.3 OPENINGS. OPEN GUARDRAILS
 SHALL HAVE INTERMEDIATE RAILS OR ORNA-
 MENTAL PATTERNS SUCH AS A 4" DIAMETER
 SPHERE CAN NOT PASS THROUGH. A BOTTOM
 RAIL OR CURB SHALL BE PROVIDED THAT WILL
 REJECT THE PASSAGE OF 2" DIAMETER
 SPHERE.
 ***GUARDRAILS WITHIN THE DWELLING UNIT
 MAY BE 36" TALL.
  
 9) SHEET A-3 FIRST FLOOR BATHROOM SHALL
 REQUIRE A 29" CLEAR OPENING, SEE 11-11.1
  
 10)PROVIDE AN ASSUMED PROPERTY LINE
 BETWEEN ALL BUILDINGS AS PER TABLE 600.
 705.1.1.2 EVERY EXTERIOR WALL WITHIN 15'
 OF A PROPERTY LINE SHALL BE EQUIPPED
 WITH OPENING PROTECTIVES, SEE UNITS
 1 & 12/ 8 & 9. GARAGE DOORS, WINDOWS &
 EXTERIOR DOORS WITHIN 15' OF ASSUMED
 PROPERTY LINE.
  
 11) TABLE 600 ASSUMED PROPERTY LINE
 BETWEEN BUILDINGS, PLANS DO NOT PROVIDE
 IF THIS IS TYPE V OR VI CONSTRUCTION.
 IF ASSUMED TYPE VI CONSTRUCTION, ASSUMED
 PROPERTY LINE BETWEEN BUILDINGS PROVIDES
 40% ALLOWABLE OPENINGS. THE FIRST FLOOR
 WITH GARAGE DOORS IS OVER THE ALLOWABLE
 LIMIT OF 40% (FLOOR TO CEILING)THE
 LENGHT OF THE BUILDING 10'-20'. IF BUILD
 ING IS TYPE V THEN 10'-20' ALLOWABLE
 OPENINGS ARE 20% (FLOOR TO CEILING).
  
 12) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 SHEET A-7 WALL SECTION# 2, WHAT FLOOR
 FRAMING IS SHOWN DIRECTLY BEHIND THE
 LEDGER 3RD FLOOR FRAMING? ALSO IN SAME
 DETAIL MISSING 2ND FLOOR CEILING FRAMING
 AT WALL LINE.
  
 13)2309.7.1 /103.7 VENTILATION OF ATTIC
 SPACE VS. ALTERNATE MATERIALS & METHODS.
 THE CODE ADVISORY BOARD DOES RECOGNIZE
 THE ALTERNATE MATEERIALS AND CONDITIONS,
 COMPLIANCE HAS NOT BEEN ACHIVED ON POINT
 #3, WHEN UNVENTED ATTIC SYSTEMS ARE SPEC
 IFIED IN CONJUNCTION WITH ASPHALT BASED
 ROOFING PRODUCTS, THE ROOFING MATERIAL/
 SYSTEM MANUFACTURER SHALL PROVIDE AN
 AFFIDAVIT CERTIFYING USE OF THEIR PRO-
 DUCT OVER AN UNVENTED ATTIC SYSTEM.
  
 14)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
 GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) WINDOWS FIXED & OPERATABLE
 B) EXTERIOR DOORS, SLIDING, SWING OR
 GARAGE DOORS
 C) MULLIONS VERTICAL & HORIZONTAL
 D) STORM SHUTTERS
 E) STRUCTURAL COMPONENTS- TRUSS ANCHORS
 F) STRUCTURAL COMPONENTS- RAILINGS
 G) ROOFING ASSEMBLIES
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 15)STORM SHUTTERS:
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PREMIT
 ISSUANCE.
  
 16) 1606.4.4 ANCHOR METHODS. PROVIDE
 INFORMATION FOR INSTALLATION OF DOOR
 AND WINDOW BUCKS.
  
 17) 1707.4.3 EACH EXTERIOR DOOR
 ASSEMBLY NOT COVERED BY 1707.4.2
 (GLAZED DOORS) SHALL BE LISTED AND TEST-
 ED FOR A PERIOD EQUAL TO THE QUANITY
 3600/ V WHERE THE TIME PERIOD IS IN
 SECTIONS AND V IS IN MILES PER HR TAKEN
 FROM FIGURE 1606. THE TIME PERIOD SHALL
 ALSO INCLUDE A 10 SECOND PERIOD AT A
 LOAD EQUAL TO 1.5 TIMES THE DESIGN
  
 18) 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 19) 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 20) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 SHEET A-7 DETAIL 2 INDICATES THE USE OF
 PB GALVANIZED METAL, IS THIS FLAT OR
 3/8" RIBBED LATH? ASTM C 1063 FOR FLAT
 DIAMOND LATH WEIGHT 2.5,2.75 OR 3.4 USE
 ON CEILINGS ARE REDUCED:
 2.5= 12"
 2.75= 16"
 3.4= 16"
  
 21) 1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 22)301.13.1 GROUND MOUNTED A/C UNITS:
 GROUND-MOUNTED UNITS FOR R3 RESIDENTIAL
 APPLICATIONS MAY BE ANCHORED WITH # 14
 SCREWS WITH GASKETED WASHERS ACCORDING
 TO THE FOLLOWING:
 1) FOR UNITS WITH SIDES LESS THAN 12",
 ONE SCREW SHALL BE USED AT EACH SIDE OF
 THE UNIT.
 2) FOR UNITS BETWEEN 12" & 24", TWO
  
 23) PROVIDE RISE & RUN OF STAIRS.
  
 24)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIP-
 TION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026