Date |
Text |
2004-09-16 00:00:00 | DENIED |
| REFERENCE: FBC-2001 PLUMBING |
| FBC-2001 CHAPTER 1 |
| FBC-2001 CHAPTER 11 |
| FLORIDA STATUTES |
| FLORIDA ADMINISTRATIVE CODE |
| |
| 1) THERE IS MORE WORK SHOWN ON THE PLAN |
| THAN IS SHOWN ON APPLICATION. PLEASE |
| CLARIFY. SECTION 104.2.1 |
| 2) INDEX OF DRAWINGS SHOWS SHEETS A-1, & |
| E-1, BUT THE ONLY SHEET SUBMITTED IS A-2 |
| PLEASE CLARIFY. SECTION 104.2.1 |
| 3) PER TABLE 403.1 A DRINKING FOUNTAIN |
| IS REQUIRED. ALSO SEE SECTION 410.1 |
| 4) SHOW THE FOLLOWING INFORMATION ON THE |
| ACCESSIBLE TOILET DETAIL. SECTION 11-4. |
| 16.2 CLEAR FLOOR SPACE, SECTION 11-4.16. |
| 5 FLUSH CONTROLS, 11-4.19.3 CLEAR FLOOR |
| SPACE, & 11-4.19.4 EXPOSED PIPES AND |
| SURFACES. |
| 5) SHT A-2 ACCESSIBLE TOILET DETAIL |
| SHOWS 18" MINIMUM CENTER TO CENTER OF |
| BETWEEN THE W/C AND LAV. MINIMUM OF 30" |
| IS REQUIRED PER SECTION 405.3.1 |
| 6) A SANITARY AND WATER RISER DIAGRAM |
| ARE REQUIRED PER SECTION 104.3.1.1 |
| 7) PER SECTION 704.5 NO DEAD ENDS ALLOW- |
| ED WHEN REMOVING PIPING FROM THE SANIT- |
| ARY SYSTEM. ABANDONED PIPING SHALL BE |
| INSPECTED PRIOR TO COVERING. |
| 8)A PROFESSIONAL ENGINEER SHALL SIGN HIS |
| NAME AND AFFIX HIS SEAL TO ALL PLANS, |
| SPECIFICATIONS, REPORTS AND FINAL BID |
| DOCUMENTS PROVIDED TO THE OWNER OR THE |
| OWNER'S REPRESENTATIVE, OR OTHER DOCU- |
| MENTS PREPARED OR ISSUED BY SAID REGIS- |
| TRANT AND BEING FILED FOR PUBLIC RECORD. |
| THE DATE THAT THE SIGNATURE AND SEAL IS |
| AFFIXED AS PROVIDED HEREIN SHALL BE EN- |
| TERED ON SAID PLANS, SPECIFICATIONS, RE- |
| PORTS, OR OTHER DOCUMENTS IMMEDIATELY |
| UNDER THE SIGNATURE OF THE PROFESSIONAL |
| ENGINEER, FAC 61G15-23.002(1)/FS 471.025 |
| INITIALS ARE NOT ACCEPTABLE. |
| EACH SHEET OF PLANS AND PRINTS WHICH |
| MUST BE SEALED UNDER THE PROVISIONS OF |
| CHAPTER 471 SHALL BE SEALED, SIGNED AND |
| DATED BY THE PROFESSIONAL ENGINEER IN |
| RESPONSIBLE CHARGE. FAC 61G15-23.002(2) |
| FS 471.025 - FULL SIGNATURE REQUIRED. |
| ENGINEERS SHALL LEGIBLY INDICATE THEIR |
| NAME, ADDRESS AND LICENSE NUMBER ON EACH |
| SHEET. IF PRACTICING THROUGH A DULY |
| AUTHORIZED ENGINEERING BUSINESS, ENGIN- |
| EERS, ENGINEERS SHALL LEGIBLY INDICATE |
| THEIR NAME AND LICENSE NUMBER, AS WELL |
| AS, THE NAME, ADDRESS AND CERTIFICATE OF |
| AUTHORIZATION NUMBER OF THE ENGINEERING |
| BUSINESS ON EACH SHEET. A TITLE BLOCK |
| WILL SATISFY THIS REQUIREMENT. FAC |
| 61G15-23.002(2) - FS 471.025 |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 653-2692 |
| E-MAIL [email protected] |