2004-08-21 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | 1) FBC-2001424.2.6.6.4 MINIMUM OF TWO | | SUCTION INLETS SHALL BE PROVIDED FOR EA | | PUMP. SEPARATED BY A MINIMUM OF 3 FEET | | OR LOCATED ON TWO DIFFERENT PLANES. | | (DETAIL) - SUPPLY INFORMATION ON THE | | "BADU" PUMP (4HP) AND SHOW HOW THIS WILL | | COMPLY WITH THE ABOVE REQUIREMENT. | | - ALSO PLANS STATE "SEE MANUF. SPECS. | | FOR BADU JET" - SUBMIT SPECS FOR REVIEW | | AND FOR INSPECTORS AT TIME OF INSPECTION | | SECTION 104.2.1 | | 2) INDICATE ON EQUIPMENT LAYOUT THE NUM- | | BERS AND LETTERS FROM THE LEDGEND FOR | | THE BADU SYSTEM. SECTION 104.2.1 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|