Date |
Text |
2004-09-21 00:00:00 | DENIED |
| |
| 1) IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY, PLANS STAMPED BY THEM AND |
| COPY OF RECEIPT SUBMITTED TO CITY OF |
| WEST PALM BEACH BUILDING DEPARTMENT, |
| BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| |
| 2) SUBMIT (2) COPIES OF LOT SURVEY. |
| |
| 3) SUBMIT AN ADDITIONAL COPY OF THE SOIL |
| REPORT. |
| |
| 4) SPECIFY THE METHOD OF TERMITE |
| PROTECTION THAT WILL BE USED ON THE |
| PLANS. SEE FBC 1816. |
| |
| 5) CITY OF WEST PALM BEACH AMENDMENTS TO |
| FBC TABLE 2306.1 REQUIRES ROOF SHEATHING |
| TO BE NAILED WITH 8D RING SHANK NAILS IN |
| ZONE 3 FOR STRUCTURES WITH A MEAN ROOF |
| HEIGHT OF 25'-35'. REVISE SHEET S3. |
| |
| 6) SPECIFY ON THE PLANS THAT DOWNSPOUTS |
| ARE REQUIRED TO DISCHARGE AT LEAST ONE |
| FOOT FROM EXTERIOR WALLS AS REQUIRED BY |
| FBC 1804.1.6 AND 1503.4.4. |
| |
| 7)2304.3.4 WOOD JOIST SHALL HAVE 18" |
| CLEARENCE FROM THE BOTTOM OF JOIST TO |
| EARTH OR ELSE BE PRESSURE TREATED WOOD |
| OR NATURALLY PRESERVATIVE WOOD. |
| |
| 8) SUBMIT (2) COPIES OF THE ENERGY CALCS |
| AND MANUAL "J"S AS REQUIRED BY FBC |
| CHAPTER 13. NOTE: OWNER/AGENT IS |
| REQUIRED TO SIGN THE FORM. |
| |
| 9) SUBMIT SHOP DRAWINGS OF EXTERIOR |
| GUARDRAILS FOR APPROVAL BEFORE THEY ARE |
| INSTALLED. |
| |
| 10) PROVIDE DETAILS OF FIREPLACE AND |
| CHIMNEY CONSTRUCTION. SHOW COMPLIANCE |
| WITH FBC SECTIONS 2113 AND 2114. FBC |
| 2804.2.4 REQUIRES THE CHIMNEY TO EXTEND |
| 3' ABOVE THE HIGHEST POINT WHERE IT |
| PASSES THROUGH THE ROOF AND AT LEAST 2' |
| HIGHER THAN ANY PORTION OF THE ROOF OR |
| BUILDING WITHIN 10' HORIZONTALLY. |
| |
| 11) SUBMIT PRODUCT APPROVAL AND |
| MANUFACTURER'S SPECIFICATIONS FOR THE |
| FLAT DECK ROOF INSULATION. |
| |
| 12)THE ROOFING MATERIAL/SYSTEM MANUFACT- |
| URE SHALL PROVIDE AN AFFIDAVIT CERTIFY- |
| ING THE USE OF THEIR PRODUCT OVER AN |
| UNVENTED ATTIC SYSTEM. SEE ATTACHMENT. |
| |
| 13) SPECIFY FIREBLOCKING IN CONCEALED |
| SPACES BETWEEN STAIR STRINGERS AT THE |
| TOPS AND BOTTOMS OF RUNS ON S2. SEE |
| FBC 2305.1.4(3). |
| |
| 14)CHANGE REFERENCE TO STANDARD BUILDING |
| CODE TO FLORIDA BUILDING CODE IN NOTE D |
| UNDER WOOD FRAMING ON S3. |
| |
| 15) PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. |
| |
| 16) SUBMIT STATE/LOCAL PRODUCT APPROVALS |
| FOR THE FOLLOWING: |
| - STRUCTURAL MULLIONS |
| - ARCHED TOP FIXED GLASS WINDOWS |
| - ROUND FIXED GLASS WINDOWS |
| - FIXED GLASS WINDOWS ABOVE FRENCH DOORS |
| |
| 17) SOME OF THE NOAS SUBMITTED HAVE |
| DRAWINGS THAT ARE MISSING INFORMATION |
| DUE TO DOWNLOADING WITHOUT SHRINKING THE |
| PAGES TO FIT ON 8-1/2" X 11" PAPER. TWO |
| COPIES OF EACH PRODUCT APPROVAL IS |
| REQUIRED. |
| |
| IF YOU HAVE ANY QUESTIONS PLEASE CALL: |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |