Plan Review Notes For Permit 04071011 |
Permit Number |
04071011 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2004-08-03 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04071011 | | ADD: 315 S OLIVE AV SUITE 104 | | CONT: RAPP CONSTRUCTION | | TEL: (561)248-6411 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) MISSING ELECTRICL PAGE? THERE IS NO | | ELECTRIC SHOWN FOR THE CORRESPONDING | | A3.1 PAGE. NO EXIT SIGNS CAN BE IDENTI- | | FIED ON THE CORRIDORS, 140, UNNUMBERED | | CORRIDOR LINKING WITH 140 TO 131, 128 | | AND 132. | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 3) UNISEX RESTROOM SHEET 8.2 GRAB BAR | | BEHIND THE WATERCLOSET, THE DIMENSION IS | | 3'-0" BUT THE PLAN IS DRAWN SHORTER? | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|