Plan Review Notes
Plan Review Notes For Permit 04061350
Permit Number 04061350
Review Stop E
Sequence Number 4
Notes
Date Text
2005-04-20 00:00:00**** UNSAT ****
  
  
  
 1)NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ON EACH LEVEL OF A MULTI-LEVEL DWELLING
 UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE
 A MIN OF 3' FROM BATHROOM DOORS AND
 KITCHENS.
 ABOVE PER:FBC 905.2, NFPA-72 8-1.4
  
 ** PLEASE SEE MISSING SD LEADING TO FLR
 ABOVE IN FIRST LEVEL IN THE VICINITY OF
 STAIRS.
 PLEASE SEE MISSING SD IN BEDRM #3.
  
 2)NOTE: PLEASE SEE MISSING PANEL "C"
 FROM PLANS.
  
 3)NOTE: PLEASE SEE "NOTE #2" ON GEN
 NOTES, IF SD'S ARE WIRED TO KIT/BATH
 LIGHTING CIRCUIT, THEN AFCI PROTECTION
 WOULD BE REQUIRED FOR THOSE CIRCUITS
 ALSO .210.12 2002 NEC
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  
  
  