2004-07-07 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
  
 1) SPA LAYOUT SHALL REFLECT THE DRAIN
 DETAIL. DRAIN DETAIL SHOWS PIPING FOR
 MAIN DRAINS AND SPA DEAINS CONNECTING AT
 THE CENTER OF THE DRAINS, BUT THE SPA
 LAYOUT SHOWS THE PIPING OFFSET FROM THE
 CENTER OF THE DRAINS. THESE SUCTION IN-
 LETS SHALL BE PLUMBED SUCH THAT WATER IS
 DRAWN THROUGH THEM SIMULTANEOUSLY. SEC.
 424.2.6.6.4. PLEASE CORRELATE DETAIL
 WITH SPA LAYOUT. SECTION 104.2.1.
 2) WHITE OUT AND HAND WRITTEN DETAILS OR
 NOTES ARE NOT APPROVED ON SIGNED & SEAL-
 ED PLANS. SECTION 104.2.1.3.
 3) PLEASE CHANGE NOTE #2 TO READ ANSI-
 NSPI-5 (STANDARD FOR RESIDENTIAL SWIMM-
 ING POOLS). HAS BEEN ANSI-NSPI 4.
  