2004-07-09 00:00:00FAILED:
 1. ALL DRIVEWAY APPROACHES THAT WILL NOT
 BE USED MUST BE REMOVED AND REPLACED
 WITH REGULAR CURB ( & GUTTERS)
 2. DDCV AND BACKFLOW ASSEMBLIES MUST BE
 LOCATED ON BACK OF THE PROPERTY LINE AND
 MADE ACCESSIBLE, PLAN SHOWS THAT THEY
 ARE FENCED. ALL DDCV AND BACKFLOWS SHALL
 BE COMPLETELY HIDDEN FROM VIEW WITH
 SHRUB.
 3. PLEASE SHOW THE FIRE DEPARTMENT
 CONNECTIONS (FDC) FOR THE PROPOSED
 STRUCTURE, MUST BE LOCATED WITHIN 150'
 MAX. FROM A FIRE HYD.
 4. ALL PARKING STALLS MUST BE PAINTED
 WITH DOUBLE 4" WIDE STRIPES, PER CITY OF
 WPB REQUIREMENT.
 5. FOR WORK WITHIN PUBLIC R.O.W
 A SEPARATE R.O.W PERMIT FROM CITY,
 FDOT, AND COUNTY AS THEY APPLY WILL BE
 REQUIRED PRIOR TO WORK BEGINS.M.O.T
 PLANS MUST BE SUBMITTED AT THE TIME OF
 APPLIACTION.
 6. ERROSION AND SEDIMENTATION CONTROL
 DEVICES MUST BE IN PLACE PRIOR TO
 BEGINNING THE PROJECT.
 IF ANY QUESTION PLEASE CONTACT 805-6723