2004-06-24 00:00:00*************** UNSAT ***************
 BLDG # 7
  
 1)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS AND CORRELATE WITH SUBMITTED
 PANLE SCHEDULE.
  
 2)NOTE: PLEASE SEE NFPA-72 FOR SD
 INSTALLATION LOCATIONS.
 3'BATHS,LITS, 20' COOKING ETC. PLEASE
 ALSO SEE EXCEPTIONS.
  
 3)NOTE: PLEASE SEE MISPRINT FOR ARC
 FAULT PROETCTION. NEC 210.12 E-8
  
 4)NOTE: PLEASE SEE CLOSET LT/ FIXTURE
 TYPE AND DISTANCE FROM SHELVES PER 410.8
  
 5)NOTE: PLEASE INDICATE A/C CU DISC'S
 PER 440.11
  
 6)NOTE: PLEASE SEE FAC 61G15-23.002,
 FS 471.023
 PLEASE INCLUDE ALL LICENSE #'S ON TITLE
 BLOCK.
 PLEASE SEE ATTACHED COPY OF DBPR PRINT
 OUT OF WEB-SITE. FIRM AS SHOWN ON TITLE
 BLOCK IS SHOWN AS HAVING A "CLOSED"
 LICENSE #.
 PLEASE SEE ABOVE IS REQUIRED ON ALL
 SHEETS AND TITLE BLOCKS WHEATHER OR NOT
 COMMENT IS MADE BY OTHER REVIEWERS.
  
 7)NOTE: PLEASE SEE OCP FOR AHU IS SHOWN
 LARGER THAN CU , YET LOAD CALCS SHOW
 CU LOAD? PLEASE CORRELATE WITH A/C PLANS
  
 PLEASE SEE COMMENTS FROM OTHER REVIEWERS
 AS THEY MAY HAVE AN AFFECT ON ELECTRICAL
 PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER