Plan Review Notes For Permit 04060859 |
Permit Number |
04060859 |
|
Review Stop |
B |
Sequence Number |
7 |
|
Notes |
Date |
Text |
2005-07-05 00:00:00 | ****CORRECTIONS**** | | TRUSS SUBMITTALS, BUILDINGS 1 - 12 | | PREPARED BY MORRIS SHASHOUA, PE | | | | 1.)THE DRAWINGS WERE NOT APPROVED BY | | EOR; HE HAS CHECKED THE BOX WHICH STATES | | "REVISE AND RESUBMIT". | | | | 2.)DOCUMENTS PREPARED BY AND ENGINEER | | AND SUBMITTED FOR PUBLIC RECORD ARE TO | | BE SIGNED, SEALED, DATED ORIGINALS | | FAC61G15-23.002. | | | | 3.)BCLL IS TO COMPLY WITH FBC TABLE | | 1605.1, MINIMUM OF 10# FOR ATTICS WITH | | NO STORAGE, 30# FOR ATTICS WITH STORAGE. | | | | 4.)THE DESIGN CRITERIA ON THE TRUSS | | LAYOUT DRAWING AND THE TRUSS ENGINEERING | | IS NOT CONSISTENT WITH THE CRITERIA | | SPECIFIED BY EOR (SHEET S0.1).EITHER | | REVISE THE PLAN OR CHANGE THE TRUSS | | DESIGN CRITERIA. | | |
|