Plan Review Notes
Plan Review Notes For Permit 04051244
Permit Number 04051244
Review Stop B
Sequence Number 1
Notes
Date Text
2004-06-24 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04051244
 ADD: 3021 OKEECHOBEE BLVD
 CONT: POPPER & ASSOC
 TEL: (561)719-7133
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIW
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL
 IS NOT DEFINITLY KNOWN OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL
 PROPERLY LICENSED IN THE STATE OF
 FLORIDA.
  
 3) FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J"
  
 4) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 5) FIRE DISTRICT NO TYPE VI CONSTRUCTION
 F102.1 WEST PALM BEACH AMENDMENT
  
 6) A-108 DETAILS INDICATE PLYWOOD SUB-
 SHEATHING- NO TYPE VI CONSTRUCTION
 ALLOWED IN FIRE DISTRICT!
  
 7) SITE PLAN INDICATES THE ACCESSIBLE
 ROUTE BETWEEN THE HUMMER SHOWROOM AND
 THE VW SHOWROOM AND THE PUBLIC WAY. THE
 PLAN ALSO INDICATES THE DROP WALK FOR AC
 CESSIBILITY, BUT NOT FOR THE ACCESSIBLE
 PARKING SPACESAND ACCESS ISLE AT THE
 HUMMER DEALERSHIP.
  
 8) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) SWING SERVICE DOOR,
 B) FIXED WINDOWS, STOREFRONT
 C) ROOFING STEELMASTER
 D) WALL LOUVERS
 E) STORM SHUTTERS- OVER LOUVERS A-112
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 9) THE A-112 SHEET INDICATES STOREFRONT
 WINDOW OPENINGS LARGER THAN THE SUBMIT-
 TED REPORT. EITHER MULLION REPORTS WITH
 THE REQUIRED LENGTH WILL BE REQUIRED OR
 DIFFERENT WINDOW REPORTS.
  
 10) THE ROOFING SYSTEM STEELMASTER
 BUILDINGS WILL REQUIRE EITHER PRODUCT
 TESTING REPORTS, (FLORIDA) OR APPROVAL
 THROUGH FLORIDA COMMUNITY AFFAIRS.
  
 11) A-111 INDICATES THE USE OF "STO
 SYSTEM" FIRE DISTRICT NO COMBUSTIBLE
 ON THE EXTERIOR OF BUILDING, F102.2.7.
  
 12) SHEET S-104 INDICATES ADDITIONAL
 INFORMATION TO BE SUPPLIED BY STEELMAS-
 TER, DECK TO BEAM CONNENCTIONS. PROVIDE
 ADDITIONAL INFORMATION.
  
 13)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved