Plan Review Notes
Plan Review Notes For Permit 04051036
Permit Number 04051036
Review Stop B
Sequence Number 4
Notes
Date Text
2005-06-13 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04051036
 ADD: 4512 N FLAGLER DR
 CONT: MHS CONSTRUCTION
 TEL: (561)577-0772
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVISION
 ACTION: DENIED
  
 STAIRS AT THE END OF THE STAIRWELL:
 APPEARS TO HAVE A SHORT LANDING.
 1007.4.2 STAIRS SHALL HAVE FLOORS OR
 LANDINGS AT DOOR OPENINGS.STAIRS
 AND INTERMEDIATE LANDINGS SHALL
 CONTINUE WITH NO DECREASE IN WIDTH ALONG
 THE DIRECTION OF EGRESS TRAVEL.THE
 WIDTH OF LANDINGS SHALL BE NOT LESS
 THAN THE WIDTH OF STAIRWAYS THEY
 SERVE.EVERY LANDING SHALL HAVE A
 MINIMUM DIMENSION MEASURED IN THE
 DIRECTION OF TRAVEL EQUAL TO THE WIDTH
 OF THE STAIRWAY.
  
 1007.5.2 STAIRWAYS SHALL HAVE HAND-
 RAILS ON EACH SIDE.
  
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026