Plan Review Notes
Plan Review Notes For Permit 04050008
Permit Number 04050008
Review Stop P
Sequence Number 1
Notes
Date Text
2004-08-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SUBMIT CALCULATIONS FOR PRIMARY AND
 SECONDARY ROOF DRAINS PER SECTIONS 1106
 AND 1107 AND ALL SUBSECTIONS. SHOW
 SQUARE FOOTAGE OF ROOF AND 1/2 AREA OF
 ALL VERTICAL WALLS INCLUDING PARAPETS
 ADDED TO SF OF ROOF AREA. INDICATE TOTAL
 AREA BEING DRAINED INTO EACH DRAIN AND
 DOWNSPOUT. SHOW SIZE OF OPENING FOR EACH
 SCUPPER AND DOWNSPOUT. SCUPPER AREA
 SHALL BE SIZED FOR TOTAL AREA DRAINED
 PLUS EMERGENCY OVERFLOW SCUPPER SIZE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]