Plan Review Notes For Permit 04042035 |
Permit Number |
04042035 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2004-06-19 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1) FROM PREVIOUS REVIEW: SHT A-1 DETAIL | | #3 SHOW COMPLIANCE FOR SECTION 11-4.24.6 | | EXPOSED PIPES AND SURFACES ON PLANS. | | 2) FROM PREVIOUS REVIEW: SHT PO.1 DOMES- | | TIC WATER ISOMETRIC, THE WATER HAMMER | | ARRESTOR SHALL BE LOCATED NEAR THE FIX- | | TURE NOT IN THE CEILING AS SHOWN. PDI-WH | | 201 AND MANUF. INSTALLATION INSTRUCTIONS | | 3) CORRECT THE CERTIFICATE OF AUTHORIZ- | | ATION NUMBER REQUIRED BY 61G15-23.002(2) | | AND FS 471.025. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|