Date |
Text |
2004-08-26 00:00:00 | DENIED |
| REFERENCE: FBC-2001 PLUMBING |
| FBC-2001 CHAPTER 1 |
| FBC-2001 CHAPTER 11 |
| FLORIDA ADMINISTRATIVE CODE |
| FLORIDA STATUTES |
| |
| 1) FAC 61G1-16.004(2) FIRM LICENSE NUM- |
| BER REQUIRED. FS 481.025 |
| 2) DPBR STAMPS AND WORKSHEETS FOR CAFE |
| TO BE SUBMITTED AT TIME OF PERMIT APPLI- |
| CATION. RESPONSE NOTED. |
| 3) DRINKING FOUNTAIN REQUIRED PER TABLE |
| 403.1 |
| 4) FROM PREVIOUS REVIEW: CONTACT RODNEY |
| COMPO, ENVIRONMENTAL COMPLIANCE FOR SIZ- |
| ING OF GREASE INTERCEPTOR. WASTE ORDIN. |
| 2938-96. (561) 837-4074. NO RESPONSE NO- |
| TED. |
| 5) FROM PREVIOUS REVIEW: SHTS P2.1A AND |
| P2.1B NOT SANITARY PIPING SHOWN FOR THE |
| TOILET ROOM IN THE CAFE OR THE TICKET |
| BOOTH. INDICATE HOW THESE WILL BE PIPED. |
| SHOW PIPE SIZE AND VENTING. |
| 6) SHTS P2.1A & P7.1 INDICATE EXISTING |
| PIPING. PLEASE CLARIFY. |
| 7) FROM PREVIOUS REVIEW: SHT P2.6 HOW |
| UPPER ROOFS SHALL BE DRAINED. SHOW CALC- |
| ULATIONS FOR ROOF AREAS BETWEEN COLS. X5 |
| AND X8. SHOW 1/2 AREA OF ALL VERTICAL |
| WALLS AND AREA OF ROOF ABOVE DRAINING ON |
| TO ROOF AREAS ADDED TO CALCULATIONS. |
| SECTIONS 1106 & 1107 AND ALL SUBSECTIONS |
| RESPONSE NOTED, BUT NO CALCULATIONS WERE |
| FOUND. |
| 8) FROM PREVIOUS REVIEW: SHTS P3.1A, |
| P3.4A, & P3.5A NO WATER SHOWN TO TOILET |
| ROOMS IN CAFE OR THE TICKET BOOTH. SECT- |
| ION 104.2.1 |
| 9) STORM FOR THE PARKING GARAGE SHOWS |
| ONLY ONE ROOF DRAIN. INDICATE HOW THE |
| RAIN WATER WILL BE DRAINED BY ONE ROOF |
| DRAIN. SUBMIT CALCULATIONS FOR THE PARK- |
| ING GARAGE SHOWING SQUARE FOOTAGE AND |
| 1/2 AREA OF ALL VERTICAL WALLS ADDED TO |
| THE SF AREA OF THE ROOF. INDICATE HOW |
| THE RAIN WATER FROM THE RAMP FROM THE |
| 5TH FLOOR TO THE 4TH FLOOR WILL BE |
| DRAINED. - WHAT WILL THE CATCH BASIN AT |
| THE NORTH END OF THE PARKING GARAGE |
| DRAIN? SECTION 104.2.1 |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 653-2692 |
| E-MAIL [email protected] |