2004-05-17 00:00:00 | BUILDING PLAN REVIEW |
| *******DENIED******* |
| ROBERT BROWN(561) 805 6716 |
| E-MAIL: [email protected] |
| |
| FBC = FLORIDA BUILDING CODE 2001 |
| FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| |
| 1) THE NOTICE OF COMMENCEMENT SHALL BE |
| RECORDED AT PALM BEACH COUNTY COURTHOUSE |
| AND A COPY SUBMITTED TO THIS OFFICE |
| BEFORE A PERMIT CAN BE ISSUED.BLANK |
| FORMS ARE AVAILABLE FROM THIS OFFICE. |
| |
| 2) IMPACT FEES. THE PLANS SHALL BE TAKEN |
| TO PALM BEACH COUNTY BUILDING DEPARTMENT |
| FOR IMPACT FEE ASSESSMENT. THEY SHALL BE |
| STAMPED AT THAT OFFICE AND A COPY OF THE |
| PAID RECEIPT SUBMITTED TO THE CITY OF |
| WEST PALM BEACH DEPT OF CONSTRUCTION |
| SERVICES BEFORE A PERMIT CAN BE ISSUED. |
| |
| 3) THE PROPOSED BUILDING STRUCTURE |
| TRANSGRESSES LEGAL BOUNDARY LINES |
| BETWEEN THE LOTS WHICH COMBINE TO FORM |
| 'THE SITE'.SUBMIT A COPY OF THE 'UNITY |
| OF TITLE' DOCUMENT SO THAT FBC TABLE 600 |
| BOUNDARY LINE REQUIREMENTS MAY BE DEEMED |
| NOT APPLICABLE. |
| |
| 4) FBC* 104.2.4SITE SURVEY.A SIGNED |
| AND SEALED SURVEY DRAWING PREPARED BY A |
| LICENSED SURVEYOR/MAPPER IS REQUIRED. |
| (REF: 472.025(1) FL. STATUTES) |
| |
| 5) FBC* 1804.2.2AREA OF QUESTIONABLE |
| SOIL.SUBMIT A GEOTECHNICAL REPORT |
| TO VERIFY THE SAFE BEARING CAPACITY OF |
| THE SOIL. |
| |
| 6) FBC 13-103.0ENERGY CODE COMPLIANCE |
| SHALL BE DEMONSTRATED BY SUBMITTAL OF |
| APPROPRIATE CODE COMPLIANCE FORMS.FOR |
| SHELL BUILDINGS, FBC 13-101.1.6 REQUIRES |
| THAT THE WHOLE BUILDING (INCL. FUTURE |
| TENANT SPACE) BE CONSIDERED.SHELL |
| BUILDINGS SHALL BE SHOWN TO COMPLY WITH |
| METHOD B (SEE SUB-CHAPTER 4).ALL |
| ASSUMPTIONS MADE ABOUT SYSTEMS, NOT |
| SHOWN ON THE CURRENT PLANS, SHALL BE |
| LISTED AND APPENDED TO THE FORM 400B FOR |
| SUBMITTAL.THIS WILL BE COMPARED, AT A |
| LATER DATE, TO THE ACTUAL SYSTEMS |
| PROPOSED BY THE FUTURE TENANT(S).THE |
| ASSUMPTIONS LISTED ON THE APPENDIX SHEET |
| SHALL BE AT LEAST THE MINIMUM STANDARD |
| (LIGHTING, HVAC ETC) TO ALLOW THE WHOLE |
| BUILDING TO BE OCCUPIED FOR IT'S |
| INTENDED PURPOSE. |
| |
| 7) FBC* 105.3RESIDENT INSPECTOR. |
| SUBMIT INSPECTOR RESUME' AND LICENSE |
| DOCUMENTS TO HAROLD PISKURA, DIRECTOR OF |
| THE RESIDENT INSPECTOR PROGRAM.A |
| RESIDENT INSPECTOR PROGRAM IS REQUIRED, |
| ON THIS PROJECT, DUE TO ONE OR MORE OF |
| THE FOLLOWING: |
| - BUILDINGS/ADDITIONS OF TYPE I OR II |
| CONSTRUCTION |
| - ANY MAJOR STRUCTURAL ALTERATIONS |
| - STRUCTURES IN WHICH THE CONCRETE |
| DESIGN IS BASED ON COMPRESSIVE |
| STRENGTH (F'C) IN EXCESS OF 3000 PSI |
| - PILE DRIVING |
| - BUILDINGS OVER 20,000 SQFT IN AREA |
| - BUILDINGS OVER 2 STORIES IN HEIGHT |
| - BUILDING/STRUCTURES OF UNUSUAL DESIGN |
| OR METHODS OF CONSTRUCTION |
| |
| 8) THE 'WORTHINGTON RD' ADDRESS SHOWN ON |
| THE TITLE BLOCK OF THE PLANS DOES NOT |
| CORRESPOND WITH THE ADDRESS SHOWN ON THE |
| PERMIT APPLICATION.CLARIFICATION/ |
| AMENDMENT IS REQUIRED. |
| |
| 9) FBC 312.1STORAGE OCCUPANCY.THE |
| PLANS SHALL BE AMENDED TO SPECIFICALLY |
| STATE THE OCCUPANCY CLASSIFICATION AS |
| 'STORAGE' SO THAT THE REQUIREMENTS FOR |
| HAZARDOUS OCCUPANCY MAY BE DEEMED NOT |
| APPLICABLE. |
| |
| 10) FBC 705.1.1.2OPENINGS IN WALLS |
| WITHIN 15 FEET OF THE PROPERTY LINE |
| SHALL BE EQUIPPED WITH APPROVED OPENING |
| PROTECTIVES.THE EXTERIOR WALL AT THE |
| WEST END IS LESS THAN 15 FEET FROM THE |
| PROPERTY LINE.AMEND THE PLANS TO |
| DEMONSTRATE COMPLIANCE.SEE ALSO THE |
| ABOVE COMMENT REQUIRING SUBMITTAL OF A |
| SURVEY DRAWING TO VERIFY SETBACKS |
| |
| 11) FBC 1007STAIR CONSTRUCTION. SUBMIT |
| DETAILS FOR THE EXTERIOR STAIR AND |
| ASSOCIATED HANDRAILS AT THE WEST END OF |
| THE BUILDING. |
| |
| 12) PROVISO: |
| SHELL BUILDING ONLY.THE BUILDING, AS |
| CURRENTLY PROPOSED SHALL NOT BE OCCUPIED |
| WITHOUT TENANT BUILD OUT TO ENSURE THE |
| REQUIRED SANITARY PROVISIONS ARE MADE. |
| |
| 13) PROVISO: |
| TILT WALL PANELS.SUBMIT SHOP DRAWINGS |
| PREPARED BY A FLORIDA REGISTERED |
| ENGINEER AND REVIEWED BY THE ENGINEER OF |
| RECORD, AS REFERENCED ON SHEET S-9. |
| |
| 14) FBC 1501.1SHEET A-9, BUILT-UP |
| ROOFING SYSTEM NOTE 07500.02.02 REFERS |
| TO THE 'ROOFING SYSTEM REQUIREMENTS OF |
| DADE COUNTY, FLORIDA'.THE ROOFING |
| SYSTEM SHALL COMPLY WITH THE MINIMUM |
| REQUIREMENTS OF SECTION 1501 OF THE |
| FLORIDA BUILDING CODE 2001 AND THE |
| STATED LIMITATIONS/INSTALLATION |
| INSTRUCTIONS OF THE PRODUCT APPROVAL. |
| |
| 15) SUBMIT PRODUCT APPROVALS FOR THE |
| BUILT-UP ROOFING SYSTEM, STOREFRONT, |
| MULLIONS, WINDOWS, EXTERIOR DOORS AND |
| OVERHEAD DOORS. |
| NOTE: FL. ADMIN CODE RULE 9B-72 (IN |
| EFFECT SINCE OCTOBER 1, 2003) REQUIRES |
| THAT PRODUCTS HAVE STATEWIDE, LOCAL OR |
| SITE-SPECIFIC PRODUCT APPROVAL.THE |
| SUBMITTAL SHOULD INCLUDE THE STATEWIDE |
| PRODUCT APPROVAL NUMBER (FL###), |
| AVAILABLE FROM THE DEPT OF COMMUNITY |
| AFFAIRS PRODUCT APPROVAL WEBSITE |
| WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP |
| |
| 16) PRODUCT APPROVAL.RULE 9B-72 FAC. |
| FOR PRODUCTS WHICH DO NOT HAVE STATEWIDE |
| PRODUCT APPROVAL, LOCAL PRODUCT APPROVAL |
| CAN BE ACHIEVED IF THERE IS A QUALITY |
| ASSURANCE PROGRAM IN PLACE WITH A STATE |
| APPROVED QUALITY ASSURANCE ENTITY.IF |
| NEITHER IS APPLICABLE, THEN SITE |
| SPECIFIC APPROVAL IS REQUIRED.LOCAL |
| PRODUCT APPROVAL WILL ALLOW A PRODUCT TO |
| BE USED, IN ACCORDANCE WITH THE TEST |
| CRITERIA, THROUGHOUT THE JURISDICTION OF |
| WEST PALM BEACH.SITE SPECIFIC PRODUCT |
| APPROVAL WILL ALLOW A PRODUCT TO BE |
| USED ONLY ON THE PROJECT FOR WHICH THAT |
| SITE SPECIFIC APPROVAL IS GRANTED. |
| LOCAL AND SITE SPECIFIC PRODUCT APPROVAL |
| APPLICATION FORMS ARE AVAILABLE FROM |
| THIS OFFICE.APPROVED QUALITY ASSURANCE |
| ENTITIES ARE LISTED ON THE DCA WEBSITE: |
| WWW.FLORIDABUILDING.ORG/COMMON/C_ORG_ |
| REGI_SRCH.ASP |
| |
| 17) TO EXPEDITE REVIEW OF A RESUBMITTAL |
| WHICH REQUIRES NEW PLANS IN ORDER TO |
| ADDRESS THE ABOVE COMMENTS, THE OLD |
| SHEETS SHALL BE REMOVED AND THE NEW |
| SHEETS INSERTED.ONE COPY OF EACH OLD |
| SHEET SHOULD BE STAPLED/CLIPPED TO THE |
| REMAINING OLD SHEETS FOR COMPARISON OF |
| REVISIONS WHEN REVIEWING THE RESUBMITTED |
| PLANS. |
| |
| **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| |
| END OF REVIEW COMMENTS |