Date Text
2004-06-03 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) FROM PREVIOUS REVIEW: SHOW LOCATION
 OF WATER COOLER. WATER COOLER SHALL CON-
 FORM TO ARI-1010. SUBMIT MANUF. SPECIFI-
 CATION SHEETS INDICATING ARI-1010 COM-
 PLIANCE. SECTION 410.1.
 2) FROM PREVIOUS REVIEW: KITCHENETTE
 SINK. SHOW COMPLIANCE WITH SECTION
 11-4.24.3 KNEE CLEARANCE. AT LEAST 27"
 AND 19" DEEP REQUIRED. - 11-4.24 DEPTH
 OF SINK SHALL BE 6-1/2" DEEP MAX. - AND
 11-4.24.6 EXPOSED PIPES AND SURFACES NOT
 SHOWN.
 3) A TURNING AREA COMPLYING WITH 11-4.2.
 3 IS REQUIRED FOR KITCHENETTE SINK. SEE
 FIGURES 3A OR 3B.
 4) SEE COMMENTS FROM ELECTRICAL PLAN
 REVIEW CONCERNING SIGNATURE REQUIREMENTS
 FOR ENGINEER. FAC 61G15-23.002(1)(2) &
 FS 471.025.
  