Date |
Text |
2004-04-27 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 04040670 |
| ADD: 515 PALM ST |
| CONT: BURKHARDT CONSTRUCTION |
| TEL: (561)659-1400 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| 1) PROVIDE NOC RECORDED WITH THE CLERK |
| OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| |
| 2) FL BLD CODE 1606.1.5: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORTS,MISSING REPORTS ARE AS |
| FOLLOWS: |
| A) FRONT DOOR & SIDELIGHT |
| B) STORM SHUTTERS |
| PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. SEE |
| ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| |
| 3)TABLE 704.1 OCCUPANCY SEPERATION |
| REQUIREMENTS; GULF STREAM MARINE, THE |
| WALL SEPERATING THE WAREHOUSE FROM THE |
| OFFICE ALSO NEEDS TO HAVE A 2HR RATING. |
| SEE 704.2.2(4) IF THE OFFICE SPACE COMPL |
| IES WITH SECTION ABOVE (< 1/3RD OF THE |
| MAJOROCCUPANCY FLOOR AREA IN WHICH IT IS |
| LOCATED, THEN NO RATING WOULD BE NECESS- |
| ARY. AS DESIGNED THE DOOR SEPERATING THE |
| OFFICE FROM THE WAREHOUSE NEEDS TO BE |
| A 1 1/2 HR RATING. |
| |
| 4)NEW KITCHENETTE SINK HEIGHT MAX. 34" |
| 11-4.24.2 |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |