Date |
Text |
2004-04-06 00:00:00 | DENIED |
| REFERENCE: FBC-2001 PLUMBING |
| FBC-2001 CHAPTER 1 |
| FBC-2001 CHAPTER 11 |
| FLORIDA ADMINISTRATIVE CODE |
| FLORIDA STATUTES |
| |
| 1) SHT A-1 KITCHEN SINK SHALL BE ACCESS- |
| IBLE ROOM #10. SUBMIT A DETAIL SHOWING |
| COMPLIANCE WITH 11-4.24 AND ALL SUBSECT- |
| IONS. |
| 2) SHT A-1 TURNING AREA REQUIRED IN KIT- |
| CHEN AREA ROOM #10. SECTION 11-4.2.3 |
| SHOW ON FLOOR PLAN. |
| 3) TABLE 403.1 A DRINKING FOUNTAIN IS |
| REQUIRED. ALSO SEE SECTION 410.1 |
| 4) SHT P-1 RPZ BACKFLOW SHALL BE LOCATED |
| 4' ABOVE FLOOR MAX. FOR SERVICING AND |
| CERTIFICATION. DRAIN TO INDIRECT WASTE. |
| 5) SHT P-1 WATER HEATER DETAIL. THERMAL |
| EXPANSION CONTROL REQUIRED. SECTION |
| 607.3.2 - P/T RELIEF DISCHARGE SHALL NOT |
| HAVE ANY TRAPPED SECTIONS. 504.7.1 |
| 6)A PROFESSIONAL ENGINEER SHALL SIGN HIS |
| NAME AND AFFIX HIS SEAL TO ALL PLANS, |
| SPECIFICATIONS, REPORTS AND FINAL BID |
| DOCUMENTS PROVIDED TO THE OWNER OR THE |
| OWNER'S REPRESENTATIVE, OR OTHER DOCU- |
| MENTS PREPARED OR ISSUED BY SAID REGIS- |
| TRANT AND BEING FILED FOR PUBLIC RECORD. |
| THE DATE THAT THE SIGNATURE AND SEAL IS |
| AFFIXED AS PROVIDED HEREIN SHALL BE EN- |
| TERED ON SAID PLANS, SPECIFICATIONS, RE- |
| PORTS, OR OTHER DOCUMENTS IMMEDIATELY |
| UNDER THE SIGNATURE OF THE PROFESSIONAL |
| ENGINEER, FAC 61G15-23.002(1) |
| FS 471.025 |
| EACH SHEET OF PLANS AND PRINTS WHICH |
| MUST BE SEALED UNDER THE PROVISIONS OF |
| CHAPTER 471 SHALL BE SEALED, SIGNED AND |
| DATED BY THE PROFESSIONAL ENGINEER IN |
| RESPONSIBLE CHARGE. FAC 61G15-23.002(2) |
| FS 471.025 - PER FBPE'S RULING INITIALS |
| ARE NOT ACCEPTABLE. FULL SIGNATURE REQ'D |
| ENGINEERS SHALL LEGIBLY INDICATE THEIR |
| NAME, ADDRESS AND LICENSE NUMBER ON EACH |
| SHEET. IF PRACTICING THROUGH A DULY |
| AUTHORIZED ENGINEERING BUSINESS, ENGIN- |
| EERS, ENGINEERS SHALL LEGIBLY INDICATE |
| THEIR NAME AND LICENSE NUMBER, AS WELL |
| AS, THE NAME, ADDRESS AND CERTIFICATE OF |
| AUTHORIZATION NUMBER OF THE ENGINEERING |
| BUSINESS ON EACH SHEET. A TITLE BLOCK |
| WILL SATISFY THIS REQUIREMENT. FAC |
| 61G15-23.002(2) - FS 471.025 |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 653-2692 |
| E-MAIL [email protected] |