2004-12-14 00:00:00 | DENIED |
| |
| 1. 713.13 F.S.A NOTICE OF |
| COMMENCEMENT |
| SHALL BE RECORDED AT PALM BEACH COUNTY |
| COURTHOUSE AND A COPY SUBMITTED TO THIS |
| OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| BLANK FORMS ARE AVAILABLE FROM THIS |
| OFFICE. |
| NOTE: THE NOTICE OF COMMENCEMENT MUST |
| BE |
| RE-RECORDED IF THE DESCRIBED |
| IMPROVEMENT |
| OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| 90 DAYS OF RECORDING. |
| |
| 3. PRODUCT APPROVALS: |
| MISSING FOR ROOFING AND FIXED GLASS. |
| PLEASE SUBMIT 2 COPIES, WITH ATTACHED |
| STATE APPROVAL. |
| PC ALUMINUM DOOR HAS WRONG STATE |
| APPROVAL ATTACHED. |
| |
| 4. C) PERMIT VALUATION HAS BEEN REVISED |
| TO $650,000 AND ADDITIONAL PERMIT FEES |
| OF $7162.56 ARE DUE. |
| |
| 5. SHOW DETAILS FOR THE FOLLOWING: |
| |
| |
| 1015.2 HEIGHT. GUARDRAILS SHALL |
| FORM A VERTICAL PROTECTIVE BARRIER NOT |
| LESS THAN 42" HIGH. |
| 1015.3 OPENINGS. OPEN GUARDRAILS |
| SHALL HAVE INTERMEDIATE RAILS OR ORNA- |
| MENTAL PATTERNS SUCH AS A 4" DIAMETER |
| SPHERE CAN NOT PASS THROUGH. A BOTTOM |
| RAIL OR CURB SHALL BE PROVIDED THAT WILL |
| REJECT THE PASSAGE OF 2" DIAMETER |
| SPHERE. |
| |
| 6.SHOW ATTIC ACCESS SIZE AND LOCATION |
| COMPLYING WITH FBC 2309.6 |
| |
| 7.SHOW ROOF DRAIN CALCULATIONS |
| INCLUDING SCUPPER SIZE HEIGHT OF PARAPET |
| WALL AND SQUARE FOOT AREA IN EACH DRAIN |
| AREA. |
| |
| 9.ENERGY CALCS NOT SIGNED BY |
| OWNER/AGENT. |
| |
| 10. SEE ELECTICAL NOTES #5 REGARDING |
| SMOKE DETECTORS.FBC 905.2 |
| |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |