2004-03-31 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT A-2 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS.
 A) MINIMUM 3" TO WATER CLOSET. TABLE
 710.1(1) FOOTNOTE A.
 B) CLEAN OUT REQUIRED 4' ABOVE FLOOR AT
 WASHMACHINE. SECTION 708.9
 C) STANDPIPE REQUIRED AT WASH MACHINE
 SECTIONS 1002.1 & 802.4.
 D) WASH MACHINE SHALL CONNECT BELOW
 WASTE ARM OF THE KITCHEN SINK. SECTION
 706.3
 2)ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  