2004-04-05 00:00:00 | BUILDING REVIEW CHECKLIST: |
| 1-ENERGY CALCULATIONS ARE NOT CALCULATED |
| FOR WORST CASE SCENARIO.THEY CAN'T BE |
| SUBMITTED AS TYPICAL FOR THIS MODEL. |
| PROVIDE ENERGY CALCULATIONS FOR WORST |
| CASE SCENARIO OR PROVIDE ENERGY CALCS |
| THAT ARE CALCULATED FOR EACH HOUSE |
| ACCORDING TO THE ORIENTATION OF IT. |
| 2-ENTRY DOOR PRODUCT APPROVAL: DRAWINGS |
| DON'T MATCH PRODUCT APPROVAL. DRAWINGS |
| ARE FOR "BENCHMARK" & PRODUCT APPROVAL |
| COVER IS FOR "THERMA TRU" DOORS. |
| 3-PROVIDE FLORIDA PRODUCT APPROVAL COVER |
| PAGE FOR SLIDING GLASS DOORS AND FIXED |
| WINDOWS. AND PROVIDE ONLY THE DWGS FOR |
| WINDOWS AND DOORS TO BE INSTALLED IN |
| THIS HOUSE. |
| 4-DETAIL E/4 AND RESIDENTIAL NOTES ON |
| DWG #2 DON'T MATCH. DETAIL E/4 CALLS |
| FOR 6"O.C. SPACING, WHILE NOTES CALL |
| FOR 16"O.C. REVISE AS REQUIRED. |
| 5-TYPICAL WALL SECTION A/4. SPECIFY |
| WHERE ARE TABLES 6 AND 8 FOR ROOF TILE |
| FASTENING TAKEN FROM. SEC. 104.2.1.2 |
| CITY AMENDMENTS TO FBC 2001. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| JULIO GOMEZ AT 805-6712. |