Date |
Text |
2004-03-31 00:00:00 | DENIED |
| REFERENCE: FBC-2001 424.2 SWIMMING POOLS |
| FLORIDA ADMINISTRATIVE CODE |
| FLORIDA STATUTES |
| |
| A) PLEASE ADJUST YOUR NOTES, DETAILS, OR |
| SUBMITTALS TO REFLECT THE FOLLOWING IN- |
| FORMATION REQUIRED FOR PLAN REVIEW |
| 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE |
| WITH ANSI/ASME A112.19.8M. PROVIDE MODEL |
| NUMBER AND MANUF INFO FOR VAC LOCK. |
| (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES) |
| 2) FBC-2001424.2.6.6.4 MINIMUM OF TWO |
| SUCTION INLETS SHALL BE PROVIDED FOR EA |
| PUMP. SEPARATED BY A MINIMUM OF 3 FEET |
| OR LOCATED ON TWO DIFFERENT PLANES. |
| (DETAIL) - MORE INFORMATION REQUIRED - |
| INDICATE THE SUCTION INLETS FOR THE 2ND |
| PUMP AS ONLY TWO MAIN DRAINS ARE SHOWN. |
| 3) FBC-2001424.2.7.1 POOL CIRCULATING |
| PUMPS SHALL BE EQUIPPED ON THE INLET |
| SIDE WITH AN APPROVED TYPE HAIR AND LINT |
| STRAINER WHEN USED WITH A PRESSURE FIL- |
| TER. (DETAIL OR ADD TO NOTES) - SECOND |
| CIRCULATING PUMP SHOWS NO HAIR AND LINT |
| STRAINER. PLEASE CLAIRFY. |
| 4) PIPING SCHEMATIC, SHOWS A SECOND |
| MANIFOLD WITH NUMBERS 1, 2, AND 5 BUT |
| DOES NOT SHOW WHERE THE SECOND SET OF |
| MAIN DRAINS (1), SKIMMER DRAIN LINE (2), |
| AND VACUUM CLEANING LINE CONNECT TO A |
| PUMP. PLEASE CLAIRFY. |
| 5)A PROFESSIONAL ENGINEER SHALL SIGN HIS |
| NAME AND AFFIX HIS SEAL TO ALL PLANS, |
| SPECIFICATIONS, REPORTS AND FINAL BID |
| DOCUMENTS PROVIDED TO THE OWNER OR THE |
| OWNER'S REPRESENTATIVE, OR OTHER DOCU- |
| MENTS PREPARED OR ISSUED BY SAID REGIS- |
| TRANT AND BEING FILED FOR PUBLIC RECORD. |
| THE DATE THAT THE SIGNATURE AND SEAL IS |
| AFFIXED AS PROVIDED HEREIN SHALL BE EN- |
| TERED ON SAID PLANS, SPECIFICATIONS, RE- |
| PORTS, OR OTHER DOCUMENTS IMMEDIATELY |
| UNDER THE SIGNATURE OF THE PROFESSIONAL |
| ENGINEER, FAC 61G15-23.002(1) |
| FS 471.025 |
| EACH SHEET OF PLANS AND PRINTS WHICH |
| MUST BE SEALED UNDER THE PROVISIONS OF |
| CHAPTER 471 SHALL BE SEALED, SIGNED AND |
| DATED BY THE PROFESSIONAL ENGINEER IN |
| RESPONSIBLE CHARGE. FAC 61G15-23.002(2) |
| FS 471.025 - INITIALS ARE NOT ACCEPTABLE |
| PER FBPE'S RULING. |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 653-2692 |
| E-MAIL [email protected] |