2004-04-23 00:00:00 | BUILDING REVIEW PROVISO: |
| 1-PROVIDE COMPLETE PRODUCT APPROVAL |
| ASSEMBLY FOR FRENCH DOORS W/ SIDELITES |
| AND TRANSOM ABOVE ASSEMBLY AS SHOWN ON |
| PLANS. SPECIFY ALL FASTENERS INCLUDING |
| ATTACHMENT OF MULLION TO WALL AND DOOR |
| AND WINDOW ATTACHMENT TO MULLION. SEC. |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| 2-PROVIDE COMPLETE DETAIL FOR STRUCTURAL |
| FACIA AT REAR PORCH. SPECIFY ALL |
| FASTENERS. SEC. 104.2.1.2 OF CITY |
| AMENDMENTS TO FBC 2001. |
| 3-PROVIDE COMPLETE DETAIL SHOWING |
| INSTALLATION OF (2)B1 CONNECTORS AT |
| THE ENDS OF GIRDER TRUSSES AT ENTRY |
| PORCH. SECTION 104.2.1.2 CITY |
| AMENDMENTS TO FBC 2001. |
| 4-PROVIDE FLORIDA/LOCAL PRODUCT APPROVAL |
| FOR ENTRY DOORS WITH IMPACT GLAZING AS |
| CALLED FOR IN SHEET A1. |
| 5-PROVIDE COMPLETE KNEE WALL SECTION/DET |
| AT ENTRY PORCH. SEE ROOF FRAMING PLAN |
| AND PROVIDE ALSO A DETAIL SHOWING HOW |
| IS 2X4 KNEE WALL ATTACHED TO TRUSSES |
| BELOW IF TRUSSES RUN PARALLEL TO THE |
| KNEE WALL. SEC. 104.2.1.2 CITY |
| AMENDMENTS TO FBC 2001. |
| 6-IF STORM SHUTTERS ARE TO BE INSTALLED |
| IN THIS HOUSE, THEN PROVIDE COMPLETE |
| INFORMATION UNDER A SEPARATE PERMIT. |