2004-09-15 00:00:00CHECKLIST:
 1-MODEL WAS CHANGED. NEED SURVEY SHOWING
 NEW MODEL LAYOUT FOR ZONING APPROVAL.
 2-NOTICE OF COMMENCEMENT IS EXPIRED.
 NEED RENEWED ONE.
 3-A)NEED FLORIDA/LOCALPRODUCT APPROVAL
 FOR FIXED WINDOWS WITH SIZES AS SHOWN
 ON PLAN. EG: SEE LENGTH OF WINDOW AT
 KITCHEN AREA.
 B)NEED FLORIDA/LOCAL PRODUCT APPROVAL
 FOR SINGLE HUNG WINDOWS.
 4-A)MULLION PRODUCT APPROVAL:
 CLEARLY INDICATE SIZE OF MULLIONS AND
 ANCHOR TYPE AND SPACING TO BE USED IN
 ORDER TO CHECK IF IT WILL MEET THE
 DESIGN PRESSURES CALCULATED ON PLANS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 5-CLEARLY SPECIFY HOW ARE FIXED WINDOWS
 AND DOORS ATTACHED TO THE STRUCTURAL
 MULLIONS. SECTION 104.2.1.2 OF CITY
 AMENDMENTS TO FBC 2001.
 6-STORM SHUTTERS NOTE ON PAGE A1 CALLS
 FOR SHUTTERS ON GLAZED OPENINGS AND
 HURRICANE MISSILE IMPACT GLAZING ON
 ENTRY DOOR. PRODUCT APPROVAL PACKAGE
 SUBMITTED IS FOR MISSILE IMPACT GLASS
 IN ALL DOORS AND WINDOWS EXCEPT ENTRY
 DOOR. ARCHITECT'S NOTE AND PRODUCT
 APPROVAL SUBMITTAL NEED TO MATCH.
 AND, IF ENTRY DOORS WILL NOT HAVE
 IMPACT GLASS, THEN PROVIDE COMPLETE
 INFO. FOR STORM SHUTTERS (FL. PRODUCT
 APPROVAL AND INSTALLATION SCHEDULE).
 7-DETAIL C/7 DOESN'T MATCH CONDITIONS
 SHOWN ON ROOF FRAMING. PROVIDE DETAIL
 THAT SHOWS ACTUAL CORNER CONDITION AND
 SPECIFY ALL FASTENERS. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 8-DETAIL G/7:SPECIFY HOW IS 2X4 BLOCKING
 ATTACHED TO TRUSSES. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 9-PROVIDE COMPLETE SECTION DETAIL AT
 ENTRY PORCH SHOWING HOW IS FRONT WALL
 FRAMED. SPECIFY ALL FASTENERS TOP AND
 BOTTOM AND FRAMING AROUND OPENINGS.
 SEE FRONT ELEVATION. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 10-SHEET A7: CROSS SECTIONS DRAWINGS FOR
 BEAMS AND LINTELS HAVE THE COPY OF THE
 ENGINEER'S SEAL. NEED ORIGINAL SEAL,
 SIGNATURE AND DATE FROM THE ENGINEER
 AS REQUIRED BY CHAPTER 471 FLORIDA
 STATUTES WHEN SUBMITTING DOCUMENTS FOR
 PUBLIC RECORDS.
 B)CROSS SECTIONS DRAWINGS AREN'T LEGIBLE
 NEED LEGIBLE DRAWINGS.
 11-OWES $2258.84 FOR UPDATE VALUATION
 WITH CHANGE OF MODEL, RESUBMITTAL FEE
 AND BALANCE DUE BECAUSE ONLY PARTIAL
 PAYMENT WAS PAID AT TIME OF PERMIT
 APPLICATION. ALSO, RE-SUBMITTAL FEES
 WILL BE CHARGED AT TIME OF RESUBMITTAL
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.