2004-03-31 00:00:00BUILDING REVIEW CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-PROVIDE STRUCTURAL BUCK DETAIL @ ENTRY
 DOORS SHOWING SIZE OF BUCK REQUIRED TO
 CLOSE GAP ACCORDING TO MASONRY OPENING
 SHOWN. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.
 3-ENERGY CALCULATIONS: A)SINCE THIS IS
 NOT A WORST CASE SCENARIO CALCS, THEN
 ORIENTATION OF OPENINGS NEED TO MATCH
 PLANS. ALSO, OPENINGS TO MATCH PLANS.
 B)REVISE OVERHANG LENGTH AND HEIGHT TO
 MATCH FLOOR PLANS.
 4-PROVIDE COMPLETE FLORIDA OR LOCAL
 PRODUCT APPROVAL FOR:
 A)ALL STRUCTURAL CONNECTORS.
 B)FRENCH DOORS WITH TRANSOM ABOVE SINGLE
 ASSEMBLY AS SHOWN ON PLANS.
 C)FIXED WINDOWS FOR BIG SIZES AS SHOWN
 ON PLANS.
 D)ROOF TILE
 E)WINDOW MULLIONS.
 F)GLASS BLOCK. 2 COPIES.
  
 5-PROVIDE APROVAL AND SPECS FOR BBQ AS
 REQUIRED BY SEC. 2808 FBC 2001.
 6-CLARIFY IF USING MISSILE IMPACT GLASS
 OR SHUTTERS. SEE NOTE ON SHEET A1 AND
 PROVIDE COMPLETE INFORMATION OF EITHER
 OPTION.
 7-SPECIFY FASTENERS FOR 2X4 BLOCKING AT
 ARCHED OPENINGS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 8-PROVIDE COMPLETE KNEE WALL DETAIL AT
 ENTRY PORCH. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 9-SPECIFY 7/8" MIN. STUCCO THICKNESS AT
 FRAMED WALLS AS REQ'D BY ASTM C-926.
 10-SPECIFY SAFETY GLASS AS REQUIRED BY
 SEC. 2405.2(IF NOT USING IMPACT GLASS)
 B)GLASS BLOCK TO HAVE SAFETY GLASS ALSO
 IF FACE THICKNESS IS LESS THAN 0.25".
 SPECIFY FACE THICKNESS TO BE USED.
 11-SHEET A3: A)CLARIFY IF ATTIC ABOVE
 GARAGE AREA IS DESIGNEDFOR STORAGE
 OR NOT STORAGE. ATTIC ACCESS W/ LADDER
 SUGGESTS ATTIC TO BE USED FOR STORAGE.
 IF SO, THEN PROVIDE SPECIFICATIONS.
 SEE TABLE 1604.1 FBC 2001.
 B)ATTIC LIVE LOAD IS MEASURED IN PSF,
 NOT PSI. REVISE NOTE AS REQUIRED.
 12-DRAWINGS ON SHEET A1 ARE NOT LEGIBLE.
 13-PROVIDE ATTIC ACCESS AT GUEST HOUSE.
 SEC. 2309.6 FBC 2001.
 14-PROVIDE COMPLETE SECTION THRU BAY
 WINDOW. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.
 15-PROVIDE COMPLETE LEDGER DETAIL FOR
 ROOF TRUSSES @ ENTRY PORCH. SEE PLANS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 16-PLEASE PROVIDE ONLY THE DETAILS THAT
 APPLY TO THIS HOUSE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 BACK AT 805-6712.