Date |
Text |
2004-05-11 00:00:00 | BUILDING REVIEW PROVISO: |
| 1-PROVIDE COMPLETE PRODUCT APPROVAL FOR |
| FRENCH DOORS WITH SIDELITES & TRANSOM |
| ABOVE SINGLE ASSEMBLY AS SHOWN ON |
| PLANS UNDER A SEPARATE PERMIT AS |
| AGREED UPON WITH MRS. HOLLY FROM |
| DREAMSTAR HOMES (5-11-04 BY PHONE). |
| B)ALSO, PROVIDE PRODUCT APPROVAL INFORMA |
| TION FOR ENTRY DOORS, OVAL AND ARCHED |
| WINDOWS AS SHOWN ON PLANS UNDER THIS |
| NEW MISCELANEOUS PERMIT. |
| 2-PROVIDE COMPLETE DETAIL FOR STRUCTURAL |
| FASCIA AT REAR PORCH BY CANTILEVERED |
| TRUSSES. SPECIFY ALL FASTENERS. SEC. |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| **PROVIDE DETAIL THAT MATCHES ACTUAL |
| CONDITIONS. SEE CANTILEVERED TRUSSES. |
| 3-PROVIDE COMPLETE DETAIL SHOWING |
| INSTALLATION OF (2)B1 CONNECTORS AT |
| ENDS OF GIRDER TRUSSES AT ENTRY PORCH. |
| SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| 4-PROVIDE COMPLETE KNEE WALL SECTION/DET |
| AT ENTRY PORCH. SEE ROOF FRAMING PLAN |
| AND PROVIDE ALSO A DETAIL SHOWING HOW |
| IS 2X4 KNEE WALL ATTACHED TO TRUSSES |
| BELOW THAT ARE RUNNING PARALLEL TO |
| KNEE WALL. SPECIFY ALL FASTENERS. SEC. |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| 5-CLARIFY/REVISE NOTE ON SHEET A1. ARE |
| STORM SHUTTERS TO BE USED OR NOT. IF |
| SO, THEN APPLY FOR SEPARATE PERMIT. |
| 6-REVISE STRUCTURAL BUCK DETAIL FOR |
| ENTRY DOOR TO MATCH ACTUAL CONDITIONS |
| SHOWN ON PLAN. SEE SIZE OF MASONRY |
| OPENING SPECIFIED ON PLANS. SECTION |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| 7-CLARIFY SPECS FOR CEILING INSTALLATION |
| AT REAR AND ENTRY PORCH. CLARIFY WHAT |
| IS A 1"X2" 16 PNEUMATIC FASTENER. SEC. |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| 8-COMPLETE SPECS ON DETAIL E/6. SPECIFY |
| BASE SIZE AND FASTENERS. SECTION |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |