Plan Review Notes For Permit 04020114
Permit Number 04020114
Review Stop P
Sequence Number 3
Notes
Date Text
2004-08-11 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 FROM PREVIOUS REVIEW:
 1) DUE TO CHANGE OF OCCUPANCY THE TOILET
 ROOM SHALL HAVE TO COMPLY WITH 11-4.22,
 11-4.16, 11-4.19 AND ALL SUBSECTIONS.
 - PLEASE SUBMIT A DETAIL SHOWING COMPLI-
 ANCE.
 FROM PREVIOUS REVIEW:
 2) PER COMMENT RESPONSE FOR A GREASE IN-
 TERCEPTOR, A SAMPLE POINT SHALL BE RE-
 QUIRED ON SANITARY LINE FROM DELI AREA
 AND UPSTREAM OF THE TOILET ROOM. PLEASE
 SHOW ON PLANS AND ON SANT. RISER DIAGRAM
 SECTION 104.2.1. - THE SANT. IS SHOWN AS
 DRAINING THE OPPOSITE DIRECTION, AND IF
 THIS IS THE CASE, THE TOILET ROOM SHALL
 CONNECT DOWNSTREAM OF THE HAND SINK WITH
 THE SAMPLE POINT UPSTREAM OF THAT CONN-
 ECTION. SOIL SYSTEM SHALL NOT DRAIN THRU
 THE SAMPLE POINT.
 FROM PREVIOUS REVIEW:
 5) INFORMATION MISSING ON THE TITLE
 BLOCK REQUIRED FOR FAC 61G1-16.004(6), A
 SPACE FOR PRINTED NAME OF THE PERSON
 SEALING THE DOCUMENT. FS 481.2055.
 FROM PREVIOUS REVIEW:
 6) THE ORIGINAL PERMIT APPLICATION IS
 REQUIRED FOR PERMIT.
 NEW COMMENT:
 1B) MOP SINK SHALL BE VENTED. SEE RED
 LINE CORRECTION OF RISER DIAGRAM FOR
 EXAMPLE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]