2004-02-13 00:00:00DENIED;
 1.AUTOMATIC CLOTHES WASHER REQUIRED. SEE
 FBC PLUMBING TABLE 403.2 ONE AND TWO
 FAMILY DWELLINGS.
 2.SANITARY RISER DIAGRAM NOT TO CODE.
 KITCHEN SINK IS NOT VENTED, BATHROOM
 CANNOT BE INSTALLED AS DRAWN.
 3.IS W/H 30 OR 50 GAL.?
 4.H2O RISER DIAGRAM, SHOCK ARRESTORS NOT
 AIR CHAMBERSARE REQUIRED PER SEC 604.9
 5.PLUMBING NOTE #1. BUILDING SEWER IS
 REQUIRED TO BE INSTALLED TO THE PUBLIC
 SEWER SYSTEM. SEPIC TANK NEEDS TO BE
 REMOVED.
 6.NOTE # 10 REMOVE NOTE HOT WATER SHOULD
 120 DEG. ONLY COMMERCIAL DISHWASHER
 REQUIRE 180 DEG. WATER.